Peaking factors of dry weather flows in Głogów combined sewage system

Journal Title: Civil and Environmental Engineering Reports - Year 2012, Vol 1, Issue 8

Abstract

This paper presents the results of dry weather flowrate studies in inflow and outflow channels of overflow structure PB-1. The facility is located in P.Skargi Street in Głogów. Based on the results the average daily peaking factor of dry weather sewage outflow was estimated. Low efficiency of the algorithm allows the estimation of the flow when depth of the channel is less then 20 cm and when it is not possible to perform measurements with the ultrasound probe. Pointed to inadequate reconstruction of cross-sectional shape of the channel during device configuration as the cause of getting inconsistent results. The results of corrective calculations based on Manning's formula and typical crosssections of channels were presented. Obtained results confirm the possibility of significant differences obtained when the channel parameters are configured incorrectly. Confirmed the low quality of the built-in algorithm supporting measurements at low depths, mistakenly called by the device manufacturer “Manning’s formula method”.<br/><br/>

Authors and Affiliations

I. Nowogoński, E. Ogiołda

Keywords

Related Articles

Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model

The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis...

NUMERICAL ANALYSIS OF BRIDGE GIRDER WITH COMPOSITE DOWEL SHEAR CONNECTION

The work presents a brief description of VFT-WIB® steel-concrete composite beams, examples of composite dowel shear connection shapes are presented. A steel-concrete bridge girder construction solution for the new shape...

NUMERICAL ANALYSIS OF EFFECTIVENESS OF STRENGTHENING CONCRETE SLAB IN TENSION OF THE STEEL-CONCRETE COMPOSITE BEAM USING PRETENSIONED CFRP STRIPS

One of the methods to increase the load carrying capacity of the reinforced concrete (RC) structure is its strengthening by using carbon fiber (CFRP) strips. There are two methods of strengthening using CFRP strips - pas...

EVALUATION OF THE EFFICIENCY OF USE OF AGGREGATES AND CHEMICAL COMPOUNDS FOR WINTER ROAD MAINTENANCE

The purpose of this article is to indicate the most effective chemical agents used for winter road maintenance. The research included the examination of melting speeds of snow and ice under various chemical agents, such...

Water supply system in Międzychód commune

The properly designed and exploited water supply system is very important both for consumers and management in commune. Work conditions of such systems are changing so it is necessary to know its current parameters. Now...