Peaking factors of dry weather flows in Głogów combined sewage system

Journal Title: Civil and Environmental Engineering Reports - Year 2012, Vol 1, Issue 8

Abstract

This paper presents the results of dry weather flowrate studies in inflow and outflow channels of overflow structure PB-1. The facility is located in P.Skargi Street in Głogów. Based on the results the average daily peaking factor of dry weather sewage outflow was estimated. Low efficiency of the algorithm allows the estimation of the flow when depth of the channel is less then 20 cm and when it is not possible to perform measurements with the ultrasound probe. Pointed to inadequate reconstruction of cross-sectional shape of the channel during device configuration as the cause of getting inconsistent results. The results of corrective calculations based on Manning's formula and typical crosssections of channels were presented. Obtained results confirm the possibility of significant differences obtained when the channel parameters are configured incorrectly. Confirmed the low quality of the built-in algorithm supporting measurements at low depths, mistakenly called by the device manufacturer “Manning’s formula method”.<br/><br/>

Authors and Affiliations

I. Nowogoński, E. Ogiołda

Keywords

Related Articles

DEVELOPMENT OF THE EXPERIMENTAL STAND WITH CENTRALLY LOCATED SPECIMEN FOR THE INVESTIGATION OF HEAT AND MOISTURE TRANSPORT PHENOMENA IN POROUS BUILDING MATERIALS

The paper presents development of an experimental stand with centrally located specimen for the investigation of heating and drying processes in porous building materials. Additionally, the paper contains preliminary res...

CHEMICAL SOIL DEGRADATION IN THE AREA OF THE GŁOGÓW COPPER SMELTER PROTECTIVE FOREST

Earth surface is under the continous influence of the environmental factors – both natural and anthropogenic. The significant impact on the environment can be noted in areas adjacent to the metal industry plants, in a co...

Comparison of the calculation results of heat exchange between a single-family building and the ground obtained with the quasi-stationary and 3-d transient models. Part 1: continuous heating mode

The paper provides comparative results of calculations of heat exchange between ground and typical residential buildings using simplified (quasi-stationary) and more accurate (transient, three-dimensional) methods. Such...

TEMPERATURE PROFILES IN A MICRO-PROCESSOR COOLED BY DIRECT REFRIGERANT EVAPORATION

An analytical solution to the equation for cooling of a unit, in the interior of which heat is generated, is presented. For that reason, a simplified non--stationary model for determination of the temperature distributio...

ECOLOGICAL AND ECONOMIC ASPECTS OF THE APPLICATION OF SEWAGE SLUDGE IN ENERGETIC PLANT PLANTATIONS - A SWOT ANALYSIS

Sewage sludge management in Poland is a relatively new field of waste management called “in statu nascendi”, the standards of which have not been recognized yet. It also requires the implementation of new solutions in th...

Download PDF file
  • EP ID EP346627
  • DOI -
  • Views 49
  • Downloads 0

How To Cite

I. Nowogoński, E. Ogiołda (2012). Peaking factors of dry weather flows in Głogów combined sewage system. Civil and Environmental Engineering Reports, 1(8), 29-37. https://europub.co.uk./articles/-A-346627