Percutaneous screw fixation of isolated fractures of the greater tuberosity of the humerus

Journal Title: International Journal of Orthopaedics Sciences - Year 2017, Vol 3, Issue 4

Abstract

Background: The unacceptable treatment outcome of the isolated greater tuberosity fracture of the humerus mainly due to missed diagnosis, ignorance, or when be trivialized. Patients and Methods: Twelve patients with isolated, displaced fracture of the greater tuberosity of the humerus were treated with closed reduction and percutaneous fixation using one or two screws. The indication for surgery was 3 - 5 mm of displacement in any plane in a mean fragment without comminution. The cause of injury was sports in three patients, motor car accidents in five patients, and hyper abduction-external rotation of the shoulder during a fall in four patients. Results: Radiographic union of the tuberosity was seen in all fractures. There was no heterotopic bone formation in any patient. Functional results were excellent in 8 patients (Constant score: 90.5%), good in 2 patients (Constant score: 81.5%) and satisfactory in 2 patients (Constant score: 70 %). All patients were satisfied with the outcome and the overall mean Constant score was 85.5%. Conclusion: Closed reduction and percutaneous fixation of large displaced fragment greater tuberosity fracture of the proximal humerus is a good technique providing stable fixation and less or no soft tissue complications as infection, muscle weakness, and adhesions. The technique should be done by experienced surgeon with intra-operative fluoroscopy. The screw is better used with washer for not to damage the fragment during compression.

Authors and Affiliations

Reda H Elkady, Nagi Fuda

Keywords

Related Articles

Influence of meniscal repair versus meniscectomy on ACL reconstruction in terms of knee stability and radiological imaging

Objective: To compare effect of meniscus repair and meniscectomy in patients undergoing ACL reconstruction in terms of clinical instability and radiological tunnel widening 1 year after surgery. Introduction: Meniscectom...

Results of closed reduction percutaneous screw fixation and open reduction internal fixation in tibial plateau fractures

Background: Tibial plateau fractures are common injuries that require anatomic reduction to obtain the best functional results. Advance in mechanization and acceleration of travel has been accompanied by an increase in n...

Role of precontoured clavicle plate in clavicular fractures

Plate prominence was noted in 2 patients at the end of 6 months though their functional outcome was on par with excellence according to the scoring scale. There was one case of non-union among the operated group at the e...

Medial parapatellar versus subvastus approach in total knee arthroplasty

Background: Component alignment is one of the most important factors for long term survival after total knee arthroplasty. The medial parapatellar and subvastus are two commonly used surgical approaches in total knee art...

A prospective study of using a locking compression plate as external fixator for open distal tibial fractures

Many a time, external fixation provides only temporary bony stabilization. Most external frames for the lower leg are bulky and cumbersome, causing significant problems for the patient. To circumvent these issues, they h...

Download PDF file
  • EP ID EP481459
  • DOI 10.22271/ortho.2017.v3.i4d.36
  • Views 116
  • Downloads 0

How To Cite

Reda H Elkady, Nagi Fuda (2017). Percutaneous screw fixation of isolated fractures of the greater tuberosity of the humerus. International Journal of Orthopaedics Sciences, 3(4), 256-260. https://europub.co.uk./articles/-A-481459