PERFORMANCE ANALYSIS OF VCR SYSTEM WITH VARYING THE DIAMETERS OF HELICAL CONDENSER COIL BY USING R-134A REFRIGERANT

Abstract

Vapor compression machine is a refrigerator in which the heat removed from the cold by evaporation of the refrigerant is given a thermal potential so that it can gravitate to a natural sink by compressing the vapor produced. Majority of the refrigerators works on the Vapor compression refrigeration system. The system consists of components like compressor, condenser, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. The design of condenser plays a very important role in the performance of a vapor compression refrigeration system. Effective new designs are possible through theoretical calculations, however may fail due to the reason that the uncertainties in the formulation of heat transfer from the refrigerant inside the condenser tubes to the ambient air. Hence experimental investigations are the best in terms of optimization of certain design parameters. The main objective in the present work is an attempt is made to verify the performance of existing condenser design to helical shaped condenser design and varying the length of the helical condenser coil to verifying the effect on the performance of a domestic refrigerator capacity 165lts, R-134a as refrigerant, hermetic sealed compressor. It is expected that the helical shaped condenser installation may give optimum results. Finally it is observed that by changing the conventional design to Helical shaped condenser the performance of the refrigeration system is increased.

Authors and Affiliations

R. Hussain Vali

Keywords

Related Articles

 IMPACT OF CONTINUOUS FARMING ON THE MICROBIAL AND PHYSIO-CHEMICAL CONSTITUENTS IN GROUNDWATER

 Water is one of nature’s most important gift all living things. The importance of this gift of nature is such that without it man could hardly exist. However, the major source of water is groundwater which agricul...

 EXPERIMENTAL INVESTIGATION TO PREDICT DENSITY OF P/M ALUMINIUM COPPER COMPOSITES IN COLD COMPRESSION USING SURFACE RESPONSE METHODOLOGY

 In this study, response surface methodology (RSM) has been applied for the prediction of the influence of process parameters, namely, deformation load, aspect ratio, initial relative density and copper content (%)...

 Design and Implementation of BISR for 3d Multiple SRAMS with Redundancies in a SOC

 Embedded memories contain several hundreds of memory cores which constitute a significant portion of the chip area for typical system-on-chip (SOC) designs. With the shrinking transistor size and aggressive design...

 Failure Analysis of Rollers in mill stand using Failure mode Effect Analysis

 Rolling is an important steel production process. Productivity and quality improvements in metal rolling are possible by paying a detailed attention to the various roll failure modes.A proper understanding of the...

 Tri-State DC-DC Buck Converter with Efficient Conversion Ratio

In modern electronic applications the requirement of step down dc-dc conversion is much more. To estimate this process this dc-dc buck converter is implemented with perfect duty cycles as a proposed work. The converter...

Download PDF file
  • EP ID EP143668
  • DOI 10.5281/zenodo.46535
  • Views 78
  • Downloads 0

How To Cite

R. Hussain Vali (0). PERFORMANCE ANALYSIS OF VCR SYSTEM WITH VARYING THE DIAMETERS OF HELICAL CONDENSER COIL BY USING R-134A REFRIGERANT. International Journal of Engineering Sciences & Research Technology, 5(2), 872-883. https://europub.co.uk./articles/-A-143668