Performance Evaluation of a Locally Produced Pulse Oximeter

Journal Title: Engineering and Technology Journal - Year 2025, Vol 10, Issue 01

Abstract

Most aftermarket pulse oximeters (POs) sold usually have peripheral blood oxygen saturation (SpO2) sensors with short life spans and the lack of specialized personnel to carry out the repairs result in frequent failures and replacement of the device. The study aims to solve the problems by developing a cheap, durable, easy to operate, and enhanced reflectance pulse oximeter (RPO). The testing of the device involved the SpO2 and heart rate (HR) measurements of Forty (40) healthy volunteers. From the performance evaluation, the measured data and its accuracy were satisfactory with an average accuracy and error rates of 99.7 % and 0.3 % for SpO2 while that of the HR was 97.7 % and 2.3 % respectively. Furthermore, analysis from the Bland - Altman Plot for both the SpO2 and HR showed that the locally developed PO could be used as a substitute to measure oxygen saturation and pulse rate in patients.

Authors and Affiliations

Chizoba Maryann Ndunwa , Nnenna Harmony Nwobodo -Nzeribe , Peter Eze-Steven , Chidi Henry Onwuekwu,

Keywords

Related Articles

Selection of the Contractor for the Construction of the Cinere Jagorawi (Cijago) Section Ii Toll Road, West Java Indonesia

Choosing a contractor for construction project work is not an easy job, because it requires accuracy in its determination, including in the work of the Cijago Toll Road Section II. Therefore, a method is needed, one of w...

The Extraction of Alcea Rosea Organic Dye and Its Characterization of Optical Properties

In the present study, the optical properties of a natural dye extracted from Alcea rosea flowers were investigated. The color extraction procedure was performed using a nontoxic solvent ethanol to enhance human safety an...

Performance Evaluation of a Locally Produced Pulse Oximeter

Most aftermarket pulse oximeters (POs) sold usually have peripheral blood oxygen saturation (SpO2) sensors with short life spans and the lack of specialized personnel to carry out the repairs result in frequent failures...

Analysis of Komolino-Lino River Flow Using HEC-RAS 6.4.1

Sedimentation in the Komolino-Lino River channel with a watershed area of ​​36.90 km2 has reduced the river's capacity. This causes flooding that inundates plantations, irrigated rice fields, residential areas, and socia...

Study on Pond Culture Water Quality Based On Several Physical and Chemical Parameters in Tambak Oso Village, Sidoarjo Regency

Sidoarjo Regency holds significant potential for pond culture, particularly in Tambak Oso Village, Waru District. Despite this, there has been a decline in pond production in recent years, possibly caused by deterioratin...

Download PDF file
  • EP ID EP754537
  • DOI 10.47191/etj/v10i01.06
  • Views 4
  • Downloads 0

How To Cite

Chizoba Maryann Ndunwa, Nnenna Harmony Nwobodo -Nzeribe, Peter Eze-Steven, Chidi Henry Onwuekwu, (2025). Performance Evaluation of a Locally Produced Pulse Oximeter. Engineering and Technology Journal, 10(01), -. https://europub.co.uk./articles/-A-754537