Performance Investigation of Solar Still Integrated to Solar Pond

Abstract

This paper presents the experimental studies done on a solar still integrated to the solar-pond. The solar still base was coated with granular activated carbon(GAC) for enhancing the evaporation rate. The solar-pond was used to pre-heat the inlet water supplied to solar still. 0.01m water depth was maintained in the solar still. Physical modelling of solar-pond was done in matlab to determine the optimum salinity level required for the bottom layer of solar-pond which is the heat storing zone. From the simulated results we found that 50g/Kg salinity is the optimal value that should be maintained at the bottom layer of the solar-pond.

Authors and Affiliations

Md. Irfan Ali , Bijo Joseph , Karthikeyan R, Yuvaraj R

Keywords

Related Articles

A Grid Connected Three-Port Solar Micro Inverter 

In the present scenario of increasing energy crisis Interest in ac module strategy for PV based microinverter has grown in recent years because of its improved energy harvest, improved system efficiency, lower installati...

Analysis of Circuit Breaker and Relays in Substations

There is a necessity of circuit breaker replacement with Gas circuit breaker is to meet the day by day growing load demand, to reduce the down time to upgrade the system with current technology and to provide better prot...

Shape and Size Dependent Electronic Properties of GaAs/AlGaAs Quantum Dots

We have theoretically investigated the effect of shape anisotropy and size on electronic structure of GaAs/AlGaAs quantum dots (QDs). The quantum dot is modeled by anisotropic parabolic confinement potential in the plane...

Effect of Dimension & Material Composition on Transmission Coefficient and Tunneling Current of Double Quantum Barrier Structure with Band Nonparabolicity

Transmission coefficient, eigen states and tunneling current density of a potentially symmetric quantum double barrier structure has been numerically computed using transfer matrix technique for qualitative analysis of r...

Techniques of Power Phase-Noise Optimization of 2.4 / 4.8 GHz CMOS VCO with Switched Capacitor Array Using Bondwire Inductor 

This paper presents theoretical analysis of the maximum operating frequency of proposed Source Degeneration (SD) and Conventional CML D-Latch are estimated. The approach is based on the voltage transfer function, which i...

Download PDF file
  • EP ID EP109173
  • DOI 10.9756/BIJPSIC.1100
  • Views 123
  • Downloads 0

How To Cite

Md. Irfan Ali, Bijo Joseph, Karthikeyan R, Yuvaraj R (2012). Performance Investigation of Solar Still Integrated to Solar Pond. Bonfring International Journal of Power Systems and Integrated Circuits, 2(1), 1-7. https://europub.co.uk./articles/-A-109173