PLATE-SCREW COMBINATION İN THE FIXATION OF UNSTABLE VERTEBRAL FRACTURES: (MID TERM RESULTS)

Journal Title: Journal of Turkish Spinal Surgery - Year 1994, Vol 5, Issue 1

Abstract

Thirteen patients (10 male and 3 female) with thoracal, lumbar or thoracolumbal fractures that were treated with St. George plate and pedicle screw combination were studied at mid term follow-up. The average age at time of surgery vvas 29 years, and average follow-up was 63 months. VVhile 7 of the patients had complete neurological function loss (Frankel A), 2 patients had full neurologic function (Frankel E). The other 4 patients had incompiete neurologic lesions (Frankel B(1), Frankel D. (3)). The losses of vertebral height, degree of ky-photic deformity and translation were measured on the preoperative, postoperative and the last follow-up plain radiographs. The mean preoperative angle of deformity vvas 22', the displacement percentage vvas 21% and the height losş vvas 40%. The immediate postoperative angle of deformity vvas 0', the ranslation vvas 0% and the height loss vvas 0%. At the last follow-up the mean angle of deformity vvas 4' and the mean height loss follovving the operation vvas 8%. The spinal canal and placement of the implants vvere evaluated vvith comput-ed tomography. at the last follovv-up, neurologic status of the 3 patients vvith complete neurologic function loss (Frankel A) and two patients vvith intact cord function (Frankel E) remained unchanged. Three of the re-maining 4 patients vvith complete neurologic function loss improved from A to B, and one improved dramatical-ly from A to D. Of the three patients with incompiete cord or cauda equina lesions, one improved from B to C and the rest three improved to E. There vvere no pseudoarthroses or implant failure. With its strength the plate sere w combination established the normal contours of the fractured spine. Plate-screvv combination is a cheap and effective method in the stabilisation of the spinal column after fractures.

Authors and Affiliations

Gürsel LEBLEBİCİOĞLU, Ahmet ALANAY, A. Mümtgz ALPASLAN, M. Nejat TOKGÖZOĞLU, A. Mazhar TOKGÖZOGLU

Keywords

Related Articles

EXPERIENCE OF SURGICAL TREATMENT OF SINGLELEVEL THORACIC DISC HERNIATIONS USING A COSTOTRANSVERSECTOMY APPROACH

Objective: To present the surgical results of patients with a single-level thoracic disc herniation treated by a costotransversectomy approach, and to discuss the advantages and disadvantages of this method. Patients...

MIGRATION OF CEMENT TO THE VENA CAVA INFERIOR DURING PERCUTANEOUS VERTEBROPLASTY: A CASE REPORT

Percutaneous vertebroplasty (PVP) is a minimally invasive and useful method for controlling the pain in patients with vertebral compression fractures. The migration of cement to the vena cava inferior following Polymethy...

SALVAGE OF FAILED SACRAL PEDICLE SCREW: BIOMECHANICAL COMPARISON OF ALA SCREW, BIGGER PEDICLE SCREW, POLYMETHYLMETHACRYLATE AUGMENTED PEDICLE SCREW

Background Data: Salvage procedures are needed to restore the stability of lumbosacral arthrodesis when pedicle screw fixation in the sacrum fails. Purpose: The aim of this study is to determine biomechanical diff...

LUMBAR SPINAL CANAL MORPHOMETRY

Objective: The aim of the study is to collect data of the mean morphometric values for spinal canal, dural sac and ligamentum flavum. Materials and Method: We inspected 63 MRI scans of lumbar spine that obtained i...

BIOMECHANICS OF SUBAX1AL CERVICAL SPİNE INSTRUMENTATION

BIOMECHANICS OF SUBAX1AL CERVICAL SPİNE INSTRUMENTATION

Download PDF file
  • EP ID EP676272
  • DOI -
  • Views 123
  • Downloads 0

How To Cite

Gürsel LEBLEBİCİOĞLU, Ahmet ALANAY, A. Mümtgz ALPASLAN, M. Nejat TOKGÖZOĞLU, A. Mazhar TOKGÖZOGLU (1994). PLATE-SCREW COMBINATION İN THE FIXATION OF UNSTABLE VERTEBRAL FRACTURES: (MID TERM RESULTS). Journal of Turkish Spinal Surgery, 5(1), -. https://europub.co.uk./articles/-A-676272