Platelet-rich plasma collection and preparation: a retrospective analysis of 256 cases
Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 10
Abstract
Objective To retrospectively analyze the safety and product quality of NGL XCF 3000 blood cell separator for collecting platelet-rich plasma (PRP) in 256 cases, so as to provide reference for safe collection and product quality control of PRP. Methods The data of 256 patients receiving PRP treatment in our hospital from June 2021 to June 2022 were statistically analyzed, and the differences in the collection time, circulating blood volume and the occurrence of adverse reactions to blood donation were analyzed when NGL XCF 3000 was used to collect autologous PRP among patients of different genders, ages and platelet counts. The differences in platelet content, red blood cell(RBC) contamination and white blood cell(WBC) residues in PRP products were analized. Results 1) There were no significant differences in collection time, circulating blood volume and collection volume among patients of different genders, ages and platelet counts (P<0.05). 2) The contents of WBC, RBC and platelet were not significantly different between male and female patients after collection (P<0.05); 3) The WBC contents increased with the increase of age, and the WBC residue in the elder group[ 56 to78 years old, (0.64±0.41) ×109/L] was significantly higher than that in the younger group[group 1,18 to 40 years old, (0.50±0.35)×109/L], with significant difference was Statistically significant (P<0.05). 4) The residues of WBCs and RBCs in in low platelet group [group 1, (100-150)×109/L] were higher than those in other platelet count groups, and the difference was Statistically significant (P<0.05), and the platelet count in this product was significantly lower than that in other platelet count groups (P<0.05). Conclusion The NGL XCF 3000 blood cell separator is safe and stable for PRP collection in patients with different genders, ages and platelet counts of (100-450)×109/L, and the PRP products collected can meet clinical therapeutic needs.
Authors and Affiliations
Lijuan YANG, Yan HU, Yajuan WU, Li ZHANG, Liping LIU, Tao PENG, Xinyu GAN
Serological and genetic analysis of a Bel subtype caused by a novel 29insG mutation: a case report
Objective To investigate the serological characteristics and molecular mechanism of a case of Bel subtype. Methods Serological method was used to analyze the ABO blood group of the patient, absorption and elution test wa...
Hemolytic disease of the newborn caused by anti-c in puerperant of Asian-type DEL treated by transfusion: a case report
Objective To explore a transfusion therapeutic plan for hemolytic disease of the newborn(HDN) caused by anti-c antibodies in mother of Asian-type DEL. Methods The ABO blood type and Rh phenotype of the mother and child w...
Bioinformatics analysis of HBV s gene mutation in blood donor
Objective To analyze the infectious indicators, HBV s gene mutations and changes in bioinformatics characteristics of HBV DNA+ /HBsAg- blood donor. Methods A sample of HBV DNA+ /HBsAg- was screened by PCR method, and HBs...
Analysis of laboratory tests and prevention strategies for hemolytic disease of the fetus and newborn caused by anti-M
Objective To analyze the application of serological test results in the diagnosis and treatment of anti-M-induced hemolytic disease of the fetus and newborn(HDFN), and to explore HDFN prevention strategies. Methods The s...
Quality evaluation of cryoprecipitate coagulation factors from buffy coat-derived plasma at different time periods
Objective To investigate the quality of cryoprecipitates prepared from buffy coat-derived plasma of fresh whole blood at room temperature 20℃-24℃ isolated at different time periods, explore the optimal time for preparing...