Positioning System for Burst Pipe Points in Metro Interval Fire Hydrant Systems

Journal Title: Urban Mass Transit - Year 2025, Vol 28, Issue 3

Abstract

[Objective] When water leakage accidents like pipe bursts occur in the fire hydrant system of metro intervals, the train control room will directly close the electric valves on the main pipeline remotely, cutting off water supply to the entire interval fire hydrant system. This results in significant safety risks for operations. Therefore, it is necessary to study a positioning system for burst pipe points in metro interval fire hydrant systems. [Method] A solution is proposed to install electromagnetic flowmeters and electric contact pressure gauges on interval fire protection risers to enable precise positioning of burst pipe points. Additionally, through linkage with the BAS (building automation system) for environmental and equipment monitoring, electric valves before and after the pipe burst point can be closed remotely and swiftly, minimizing the impact on the interval fire protection system. The overall architecture of the positioning system for burst pipe points in metro intervals is outlined, comprising three layers: perception layer, network layer, and application layer. [Result & Conclusion] A rapid positioning system for burst pipe points is established, enabling the remote closure of valves before and after the burst point location. This approach could minimize unprotected sections of the fire hydrant system and the metro service downtime, ensuring the metro interval resumes normal operations promptly following accidents such as pipe burst.

Authors and Affiliations

Zhengzhong WU, Wenju YU, Junping LIU, Ke LI, Zongzhou LIU, Junxia CHANG, Chao LIU, Junjie TONG, Kecheng YU

Keywords

Related Articles

Numerical Simulation of Small Unconnected Karst Caves Grouting and Crack Quantity Impact Based on Fluent Software

Objective Grouting treatment of karst caves is a challenge in metro tunnel engineering, as improper handling of karst caves during construction can easily lead to accidents. Therefore, it is necessary to study the relati...

Analysis of DC Fast Circuit Breaker Opening and Arc Extinction in Urban Rail Transit Traction Power Supply System

Objective Arc extinction technology for DC (direct current) is one of the design challenges in urban rail transit traction power supply systems. Therefore, it is necessary to analyze the principles of DC opening and arc...

Controlled Blasting Technology for Connection Passage between Metro Shield Sections in Hard Rock Stratum

Objective At present, a relatively systematic, mature and rapid excavation construction method for the connection passage construction in hard rock stratum has not been formed yet. Due to the small cross-section and limi...

Research on Energy Management Method of Fuel Cell and Supercapacitor Hybrid Power System Based on Optimal Power Consumption

Objective With the steady advancement of technology and China's dual carbon process, the application of hydrogen energy in urban transportation is increasing. To reduce the overall energy consumption of fuel cell/superca...

Design and Realization of Urban Rail Transit AFC Intelligent Operation and Maintenance System Architecture Driven by Dual-core of Data and Model

Objective The traditional urban rail transit AFC (automatic fare collection) system suffers from maintenance problems such as slow speed, outdated method, unreasonable plan and high cost. It is necessary to adopt digital...

Download PDF file
  • EP ID EP760145
  • DOI 10.16037/j.1007-869x.2025.03.025
  • Views 21
  • Downloads 0

How To Cite

Zhengzhong WU, Wenju YU, Junping LIU, Ke LI, Zongzhou LIU, Junxia CHANG, Chao LIU, Junjie TONG, Kecheng YU (2025). Positioning System for Burst Pipe Points in Metro Interval Fire Hydrant Systems. Urban Mass Transit, 28(3), -. https://europub.co.uk./articles/-A-760145