Power Quality Improvement By Usingstatcom To Grid Connected Wind Energy System

Abstract

Now a days the electrical energy is basic necessary of all over world. Due to generation, transmission and utilization of wind energy system is affected the voltage variation, flicker, harmonics, and electrical behavior of switching operations. The voltage varying, voltage stability will be loss and power factor is lagging to connect the load. In this paper we studying use of static compensator (STATCOM) with battery energy stored system (BESS) at point common coupling to minimize the power quality matter. The wind energy system is connected to grid connected power quality improvement by using of STATCOM scheme of simulated of matlab/simulink in power system of block set. The desired power system maintain voltage stability and phase difference is zero, minimize distortion, harmonics of power system according to guidelines specified in IEC61400 standard (International Electro-technical Commission) provides some norms and measurements parameter.

Authors and Affiliations

Brijesh Kumar Dohare, Raghvendra Pratap Singh

Keywords

Related Articles

Novel Three Phase Five Level Inverter with Reduced Number of Power Electronics Components

Novel three phase five level inverter with reduced number of power electronics components are introduced. This inverter consists of typical three phase two level-bridge inverter with three bidirectional switches and two...

Cuckoo Search Algorithm for Environmental/Economic Dispatch Problem

This paper proposes a new meta-heuristic search algorithm, called cuckoo search algorithm (CSA). The cuckoo search is an optimization algorithm based on the brood parasitism of cuckoo species by laying their eggs in the...

Heuristic Approach to DG Sizing and Siting in Distribution System for Voltage Drop Reduction

This paper presents the impact of penetration level and power factor of DG on the voltage drop in a distribution system. For this purpose, suitable expressions have been developed to estimate the squared voltage drop red...

Retraining air Lines 220kv Transmission in The Paraguayan Power System using High Temperature conductors and Low Sag (HTLS) And Their Feasibility.

In the present study was assessed the technical and economic feasibility to change in high voltage aerial transmission lines conventional ACSR conductors by High Temperature and Low Sag (HTLS) conductors of similar diame...

Flying with Internet of Things via Global Structure

According to growth of high definition technologies and their wide applications in each part of our life, these lead to globalize a new aspect to be an umbrella to cover and connect all things in the world. Internet of t...

Download PDF file
  • EP ID EP387230
  • DOI 10.9790/1676-1203030108.
  • Views 123
  • Downloads 0

How To Cite

Brijesh Kumar Dohare, Raghvendra Pratap Singh (2017). Power Quality Improvement By Usingstatcom To Grid Connected Wind Energy System. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(3), 1-8. https://europub.co.uk./articles/-A-387230