Power Quality Improvement, Harmonic Elimination and Load Balancing in Industrial Power System

Abstract

Non linear loads are increasingly more abundant in commercial, residential and industrial sector and their percentage of the total load are growing steadily. The increasing uses of non linear loads are becoming more harmonic problems at utilities and customers sides. The harmonic problems cause damage of system equipment and low power quality. The most appropriate solution to mitigate this issue is passive filter. Passive filters are typically composed by inductors, capacitors and resistors which are used for mitigating harmonic distortions, power factor correction and improving power quality. In this paper, simulation models are implemented for mitigating harmonic distortions by applying passive filter at No 3 .Steel Mill Ywama, Yangon in distribution system. Passive filters are installing at point of common coupling PCC of 11kV feeder in distribution system to reduce the harmonic distortion within IEEE 519 1992 standards. THD is used as the harmonic index to study the effect of harmonic distortions. In this paper, the performance of the designed filter in this network and THD are obtained from simulation using MATLAB. Myo Win Kyaw | Hnin Yu Wai | Theingi Htun "Power Quality Improvement, Harmonic Elimination and Load Balancing in Industrial Power System" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd26661.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26661/power-quality-improvement-harmonic-elimination-and-load-balancing-in-industrial-power-system/myo-win-kyaw

Authors and Affiliations

Keywords

Related Articles

Design, Development, and Performance Evaluation of a Mechanical Device for Harvesting Pineapple

Pineapple Ananas comosus in family Bromeliaceaeis a large, succulent, and tasty fruit with immense health benefits. Among all the cultivation activities of pineapple, harvesting is the most difficult, time consuming, and...

Analysis Of Drinking Water Quality Parameters (A Case Study Of Hanumangarh Town)

The present study has based on the analysis of drinking water quality parameters (A Case Study Of Hanumangarh Town) Due to the human and industries activities the water is contaminated. This is serious problem now a day....

A Study on Recent Trends in Recruitment Practices in India

Gone were the days where the traditional method of recruitment would suffice to hire potential talents. But, since few decades the recruitment process has witnessed a sea of change due to the advent of the internet and i...

Benchmarking and Employee Job Satisfaction in Adamawa State University, Mubi

Benchmarking is now a commonplace term in business and many definitions have been proposed. Despite its increasing popularity there is growing evidence that it is often used incorrectly. "˜Benchmarking"™ seems to be conf...

Implementation and Performance Evaluation of Neural Network for English Alphabet Recognition System

One of the most classical applications of the Artificial Neural Network is the character recognition system. This system is the base for many different types of applications in various fields, many of which are used in d...

Download PDF file
  • EP ID EP628890
  • DOI 10.31142/ijtsrd26661
  • Views 95
  • Downloads 0

How To Cite

(2019). Power Quality Improvement, Harmonic Elimination and Load Balancing in Industrial Power System. International Journal of Trend in Scientific Research and Development, 3(5), 1217-1221. https://europub.co.uk./articles/-A-628890