PRACTICAL STUDY TO IMPROVEMENT THE PERFORMANCE OF HEAT EXCHANGER USING PASSIVE TECHNIQUES

Abstract

The aim of this study to improve the performance of heat exchanger by using the medium integral fins on the cross flow heat exchanger practically, so, two the heat exchangers from copper were manufactures with eight passes for comparison under different boundary conditions. The water flow rate flow inner the tubes with (2, 3, 4, 5, 6) L/min with inlet temperatures (50, 60, 70) oC, as for the air flow rate were passed outer the tubes by speeds (1, 1.7, 2.3) m/sec. The results show that the medium integral finned tube gives more improvement the heat transfer than the smooth tube about 203.97% and 205.1% was enhancement factor. Motivation: The aim is improvement the heat transfer coefficient for cross flow heat exchanger by using medium integral finned tube. Study the effect of various water stream rate, air speed and inlet water temperature on heat transfer coefficient for them, Finding the cases which enhanced heat transfer for various ranges of air and water as well as inlet temperatures and the speed at the entrance. Develop the empirical correlations for (Nua) of smooth and medium integral finned tubes as function of (Pra) and (Rea).

Authors and Affiliations

Keywords

Related Articles

SEASONAL MARKETING: STRATEGIES USING THE CALENDAR

In this ever-dynamic world, the only thing that is constant is change. Change when happens, applies to all; then why should marketing remain the same? Each year is a witness to various seasons, and each season requires s...

USER INTERFACE DESIGN AND INFORMATION SYSTEMS USAGE: A CASE STUDY OF TVET INFORMATION SYSTEM AT IPRC KIGALI

The purpose of this study was to assess the effect of User Interface Design on Information Systems Usage for the Technical Vocational and Educational Training Information System at (TVET-IS) at Integrated Polytechnic and...

INDUCED PHENOLOXIDASE PROFILES IN SILKWORM Bombyx mori (L.) UNDER BIOTIC STRESS

Phenol oxidase (PO) is one of the stress enzyme protein in living organism. The conversion of Pro-PO into an activation form of PO required a stress protein. In the present study has emerged with the novel finding of ind...

EXPERIMENTAL STUDY OF INSULATOR USING ASBESTOS COATING MATERIALS WITH DIFFERENT TEMPERATURE

In this paper we are study about insulator with asbestos coating material. The applied loads are as 1000 Watts, 2000Watts, 3000Watts, 4000Watts, and 5000Watts. The coated insulators are used in distribution Line, in this...

GAS PIPELINES IN NIGERIA: SINE QUA NON FOR ECONOMIC DEVELOPMENT

The study reviewed the gas pipeline development in Nigeria and outlines needed strategies needed for sustainable development of gas pipeline for socio-economic development in Nigeria. There is inefficient gas pipeline de...

Download PDF file
  • EP ID EP618882
  • DOI 10.5281/zenodo.3370525
  • Views 109
  • Downloads 0

How To Cite

(2019). PRACTICAL STUDY TO IMPROVEMENT THE PERFORMANCE OF HEAT EXCHANGER USING PASSIVE TECHNIQUES. INTERNATIONAL JOURNAL OF ENGINEERING TECHNOLOGIES AND MANAGEMENT RESEARCH, 6(8), 21-33. https://europub.co.uk./articles/-A-618882