Prediction of Distribution Transformer Premature Failures

Abstract

This paper deals with two types of Distribution Transformer failure analysis tests which can help in monitoring the Distribution Transformers condition. The three methods are Conventional oil test, Furan derivatives test. Conventional oil testing procedures determine the gas concentrations in the Distribution Transformers oil sample and analysing the defect by considering the ratio of two suitable gasses. Furan derivative analysis includes determination of Furan derivatives present in the Distribution Transformers oil sample and helps in deciding the Distribution Transformers insulation condition. A computer program was developed for which that can help in finding out the fault probability of the Distribution Transformer. Here, we demonstrate the application of these three methods on a 132/33kV, 15MVA Distribution Transformer from CSEB substation, Korba Bilaspur, India, under three different conditions namely healthy, moderately deteriorated and extensively deteriorated conditions and results obtained.

Authors and Affiliations

Tarini Dewangan, Miss Pragya Patel

Keywords

Related Articles

A Network-Coding-Based Storage System in a Cloud-of-Clouds

NCCloud is constructed on high of a network-coding-based storage theme referred to as the practical minimumstorage make (FMSR) codes, that maintain a similar fault tolerance and knowledge redundancy as in ancient erasure...

Study of Meta, Naïve Bayes and Decision Tree based Classifiers

Classification deals with the kind of data mining problem which are concerned with prediction. Its main task is to classify the data in order to make predictions about new data. In general Classification can be viewed a...

Construction of an Ohmic Heating Apparatus and Evaluation of Electrical Conductivity of Sweet Lime Juice

Different emerging technologies for thermal food processing were developed and today’s era demands for those technologies which result in high quality with minimum processing. Ohmic heating is the volumetric method of h...

Modification for Ductile Detailing of Beam Column Joints

Earthquake resistant buildings are necessary to reduce the damage caused to structures during devastating earthquakes. One of the characteristics of earthquake resistant buildings is having an adequate design on the bea...

Introduction To Artificial Intelligence.

Artificial Intelligent is simulating the human brain in real time, complete with artificial consciousness and artificial general intelligence, whereas the "mechanisms of knowledge representation in the brain which is eq...

Download PDF file
  • EP ID EP24262
  • DOI -
  • Views 292
  • Downloads 8

How To Cite

Tarini Dewangan, Miss Pragya Patel (2017). Prediction of Distribution Transformer Premature Failures. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(5), -. https://europub.co.uk./articles/-A-24262