Proximal femoral locking plate: A good alternate in comminuted proximal femoral fractures

Journal Title: International Journal of Orthopaedics Sciences - Year 2017, Vol 3, Issue 4

Abstract

Introduction: Intertrochanteric and sub trochanteric fractures account for 50% of all fractures of the proximal femur. Surgical treatment is the preferred method in these fractures to reduce the complications of prolonged immobilization. Recently proximal femoral locking compression plate (PF-LCP) has been applied in the treatment of proximal femur fractures. Materials and methods: This is a prospective type of study of 12 cases of comminuted inter trochanteric and sub trochanteric fractures of femur treated surgically with proximal femoral locking compression plate (PF-LCP). All the cases were operated electivley on regular operation theatre days. Results: In age distribution, 6 (50%) patients were between 50-75years. The range of age was between 20-75 years, with mean age of 43.8years. In sex distribution, there were 8 (66%) males and 4(34%) females. Left lower limb was involved in 9 (75%) cases and right lower limb in 3 (25%) cases. In mode of injury, 8 cases (66%) were due to slip and fall and 4 cases (34%) were due to road traffic accident. Kickstand screw was used in 9(75%) cases and not used due to narrow femoral neck in 3(25%) cases. Proximal screw was back out two patients (16%). Varus collapse occurred in one patient (8%). Delayed union in two patients (16%). Conclusion: The PF-LCP is appropriate for complex and unstable proximal femoral fractures with poor bone quality.

Authors and Affiliations

Dr. Riyaz Babu Shaik, Dr. Satya Kumar K, Dr. Cherukuri Akhila Sai Sree

Keywords

Related Articles

Role of locking dynamic hip screw in management of inter-trochanteric fractures of femur in elderly patients

Introduction: Dynamic Hip screw is the implant of choice for most inter-trochanteric fractures of the femur. But, its most common mode of failure is for the lag screw to cut out of the femoral head, the second is for the...

Arthroscopic assisted stabilization of acute acromioclavicular dislocations by cortical fixation buttons for acute acromioclavicular dislocation

Purpose: To evaluate the results of 15 patients following  arthroscopically assisted AC joint fixation  using  cortical fixation buttons (AC tightrope or dog bone fiber tape construct) for  acute  AC joint separations. P...

Functional outcome of different treatment methods in fingertip injuries: A prospective study

Background: Various treatment modalities are used from the past to treat fingertip injuries. The common methods used are suturing, skin grafting, flap coverage of the wound by different techniques. This study reports the...

Efficacy of mesenchymal stem cells in healing of meniscus tear

Background: The meniscus is a semilunar fibro-cartilaginous tissue performing various function including knee joint stability, shock absorption, load distribution, joint lubrication, and joint congruity. Menisectomy ofte...

Locking plate fixation of mid-shaft clavicle fractures: analysis of complications, reoperation rates and functional outcome

Introduction: Clavicle fractures account for about 5-10% of all fractures and most of these fractures are located in the middle third of clavicle. Traditionally, these fractures have been treated by conservative methods....

Download PDF file
  • EP ID EP482833
  • DOI 10.22271/ortho.2017.v3.i4m.130
  • Views 100
  • Downloads 0

How To Cite

Dr. Riyaz Babu Shaik, Dr. Satya Kumar K, Dr. Cherukuri Akhila Sai Sree (2017). Proximal femoral locking plate: A good alternate in comminuted proximal femoral fractures. International Journal of Orthopaedics Sciences, 3(4), 937-940. https://europub.co.uk./articles/-A-482833