Quantitative Analysis of 30 Drugs in Whole Blood by SPE and UHPLC-TOFMS
Journal Title: Journal of Forensic Science & Criminology - Year 2013, Vol 1, Issue 1
Abstract
An Ultra-High Pressure Liquid Chromatography Time-of-Flight Mass Spectrometry (UHPLC-TOF-MS) method for quantitative analysis of 30 drugs in whole blood was developed and validated. The method was used for screening and quantification of common drugs and drugs of abuse in whole blood received from autopsy cases and living persons. The compounds included: alprazolam, amphetamine, benzoylecgonine, bromazepam, cathine, cathinone, chlordiazepoxide, cocaine, codeine, clonazepam, 7-aminoclonazepam, diazepam, nordiazepam, flunitrazepam, 7-aminoflunitrazepam, ketamine, ketobemidone, 3,4-Methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), methamphetamine, methadone, morphine, 6-monoacetylmorphine, nitrazepam, 7-aminonitrazepam, oxazepam, temazepam, tramadol, O-desmethyltramadol, and zolpidem. Blood samples (200 μL) were subjected to Solid Phase Extraction (SPE). Target drugs were quantified using a Waters ACQUITY UPLC system coupled to a Waters SYNAPT G2 TOF-MS apparatus. Extraction recoveries ranged from 41% (7-aminoclonazepam) to 111% (ketamine) and matrix effects ranged from -13% (temazepam) to 50% (7-aminonitrazepam). For all compounds, a quadratic polynomial was applied for fitting the calibration curves. Lower Limits of Quantification (LOQ) ranged from 0.005 to 0.05 mg/kg. Satisfactory precisions below 15% and accuracies within 85-115% were obtained for all compounds at concentrations exceeding the LOQ. In conclusion, we present a validated UHPLC-TOF-MS method for simultaneous quantification of 30 drugs in whole blood with a run time of 15 min using 200 μL of whole blood.
Authors and Affiliations
Dalsgaard PW
Presentation of the HoNOS-Secure French Version, an Outcome Measure for Users of Secure and Forensic Mental Health Services
Background: Despite a number of instruments designed for the assessment of dangerousness, standardized outcome measures for forensic psychiatric patients are lacking, especially in other languages than English. Aim: To...
Examination of Some Country made Smooth Bore Firearms
Present trend of the crimes in India reveals that a wide variety of firearms including factory /country made are illegally used in crimes like murder, armed robbery, riot, poaching etc. Out of the total firearms received...
Programming Scripts for Simple and Complex Paternity Testing based on Open-Source Programming Language from the R Project
Programming scripts were written for the statistical analysis of genetic data from simple cases and complex cases of undetermined paternity. The methods presented here involve algorithms constructed with R, an open-sourc...
Latent Fingerprints of Insufficient Value Can be Used as an Investigative Lead
The evidential and investigative value of a latent fingerprint with insufficient characteristics to identify can sometimes be an issue of debate. In this report the authors present the case of a latent fingerprint bearin...
The Impact of Advances in Post-Mortem Imaging on Forensic Practice
Post-mortem imaging in the form of plain X-ray films has been in use for many years as an adjunct or occasionally as a substitute for autopsy. However, in the last two decades there has been increasing interest and inves...