Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control

Abstract

In this paper a unique issue rising from feedback control of Supraventricular Tachycardia monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the Supraventricular Tachycardia heart rate signals. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Supraventricular Tachycardia system. This paper treats a remotely controlled Supraventricular Tachycardia system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Authors and Affiliations

Mohammad A. Obeidat, Ayman M Mansour

Keywords

Related Articles

Impact Study of Wind Generation on power quality of Electrical Power Grid (Jordan Wind Farm Case Study)

Renewable Energy becomes a vital part in modern power system because of; continuous increase of energy demand, global regulations about Co2 emissions, and the slash of the renewable energy prices. Wind energy is a great...

A Novel Dual Inductor DC-DC Buck Converter

A novel DC-DC Buck Converter using dual inductor and switched capacitor is proposed. Proposed circuit consists of two inductor instead of single inductor used in conventional dc-dc buck converter. The proposed converter...

Intelligent Assistant for Controlling Iot Devices

We square measure in twenty first century, wherever everything is automized from home to industrial space. Devices automation reduces the human efforts and it additionally saves energy and time. it's additionally used fo...

Smart Switch

Smart switch is a device which operates (ON/OFF) any electrical appliance with the help of mobile phone only by sending a SMS from any place (wherever GSM network is available). User sends a SMS to the mobile number, ins...

Constant voltage and Constant frequency operation of DFIG using Lab view FPGA and cRIO

This paper presents control of doubly fed induction generator using LabVIEW FPGA platform. NI LabVIEW FPGA enables fast and easy implementation of hardware control due to its graphical programming capability, inherent pa...

Download PDF file
  • EP ID EP388518
  • DOI 10.9790/1676-1301010516.
  • Views 128
  • Downloads 0

How To Cite

Mohammad A. Obeidat, Ayman M Mansour (2018). Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 5-16. https://europub.co.uk./articles/-A-388518