Refinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients

Journal Title: Electronic Physician - Year 2016, Vol 8, Issue 12

Abstract

INTRODUCTION: The Goldmann applanation tonometer readings were noted to be markedly reduced after Lasik surgery using a thin flap technique which is widely used nowadays, to correct a wide range of myopia and astigmatism. The Ocular Response Analyzer (ORA) is considered one of the important tools for refinement of Intraocular Pressure (IOP) measurements. The aim of this study is to evaluate and refine ORA measurements for IOP changes post- M2 90 Moria microkeratome Lasik procedure for Egyptian myopic and astigmatic patients trying to aid in glaucoma diagnosis and management. METHODS: Thirty-five eyes of nineteen Egyptian patients with myopia or myopic astigmatism who had undergone Lasik procedure using M2 90 Moria microkeratome were included in this consecutive case series study. All cases were subjected to full ophthalmological examination including uncorrected and best corrected visual acuity, refraction, slit lamp examination, Scheimpflug imaging and ORA (Reichert Ophthalmic Instruments, Inc., Buffalo, NY, USA). The refractive errors were measured using an auto refractometer and were confirmed by trial. For the ocular response analyzer, the Goldmann-correlated IOP measurement (IOPg) which simulates IOP measured by Goldmann tonometer and the Corneal-Compensated Intraocular Pressure (IOPcc) that takes corneal biomechanical properties into consideration were reported as well as the Corneal Hysteresis (CH) and the Corneal Resistance Factor (CRF). Cases were examined preoperatively and again about one month after Lasik, after stabilization of eye condition. The collected data were tabulated and analysed with the suitable statistical methods. The mean values and standard deviation were calculated for quantitative data. Comparison tests (t-test) and correlation tests (Pearson) were also performed. RESULTS: In our study, involving M2 90 Moria microkeratome Lasik procedure, a highly significant post-Lasik reduction in IOPg (t-test = 8.62 (p<0.01), and a statistically significant reduction in IOPcc (t-test = 3.37 (p<0.05) by ocular response analyzer. The average post-Lasik reduction in IOP in mmHg was 4.84±2.82 for IOPg and 2.23±3.51for IOPcc. A statistically significant correlation (p<0.05) existed between post-Lasik reduction of IOPg and ablation depth as well as preoperative spherical equivalent. A non-significant correlation existed between post-Lasik reduction of IOPcc and both of ablation depth and preoperative spherical equivalent. CONCLUSIONS: Following Lasik procedure using M2 90 Moria microkeratome, the IOPcc values by ORA were closer to the preoperative values than the IOPg values and the reduction of IOPcc values was not affected by ablation depth (i.e. preoperative spherical equivalent). Therefore, it is advisable to use the IOPcc values by ORA when evaluating post-Lasik patients for glaucoma diagnosis and management, but with the addition of the average value for post-Lasik reduction which in the study was 2.23±3.51mmHg

Authors and Affiliations

Refai TA, Hassanin OA

Keywords

Related Articles

Occult Hepatitis C Virus Infection in Hemodialysis Patients; Single Center Study.

A new form of hepatitis C virus infection, known as occult hepatitis C virus (HCV) infection, is characterized by the presence of HCV_RNA in the liver or peripheral blood mononuclear cells (PBMCs). However, no serologica...

Qualitative study of HIV related stigma and discrimination: What women say in Iran

Introduction: HIV-related stigma is a major social problem of people living with HIV. Stigma against these people, especially women, interferes with the prevention, diagnosis and treatment of HIV. This study examined the...

Investigation of marital satisfaction and its relationship with job stress and general health of nurses in Qazvin, Iran

BACKGROUND: Pressures in nursing can affect family life and marital problems, disrupt common social problems, increase work-family conflicts and endanger people's general health. AIM: To determine marital satisfaction a...

Status of antioxidant and homocysteine-lowering vitamins related to cardiovascular diseases in hemodialysis patients

BACKGROUND AND AIM: Cardiovascular disease is the major cause of mortality in hemodialysis patients. Oxidative stress and hyperhomocysteinemia may contribute to an increased risk of CVD. Therefore, we assessed the status...

Analysis of Amygdala Nucleus in the Rat Brain: A review study

Amygdale is one of the limbic related sub-cortical nuclei lying in the depth of temporal lobe and rostral of the inferior horn of lateral ventricle. In fact, amygdale is a nucleus complex that plays an important role in...

Download PDF file
  • EP ID EP339557
  • DOI 10.19082/3429
  • Views 100
  • Downloads 0

How To Cite

Refai TA, Hassanin OA (2016). Refinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients. Electronic Physician, 8(12), 3429-3433. https://europub.co.uk./articles/-A-339557