Reliability Assessment of APO 132/33 KV Electric Transmission Substation Abuja

Journal Title: American journal of Engineering Research - Year 2017, Vol 6, Issue 8

Abstract

This study investigate the reliability assessment of Apo 132/33kV Transmission substation, AbujaNigeriato provide adequate electrical supply to its customers as economically as possible with reasonable level of reliability. The system reliability impact data on statistical information were classified as unscheduled (forced) and scheduled(planned)maintenance outages on each feeder were collected from January to December, 2015 as documented in the daily logbooks. The data wereused to compute and analyzed the reliability indices using Microsoft and Excel package with respect to customer orientation indices of SAIFI, SAIDI, CAIDI, and ASAI using equations 1 to 4. The results shows thatunscheduled (forced) outages reliability indices for H3, H13 and H15 feeders for average service availability index (ASAI) were 0.9935, 0.9935, and 0.996; while consumer average interruption duration index (CAIDI) were 3.48, 3.7, and 2.368 respectively. The maximum CAIDI was recorded on feeder H13 in the month of October with interruption duration of 3 hours and 42 minutes. The maximum system average interruption duration index (SAIDI),recorded 17.193, 13.49, and 9.875 with the highest in June on feeder H3 and 13 hours 33 minutes. Also the maximum system average interruption frequency index (SAIFI), for the corresponding feeder’s were7.6, 6.0, and 5.7 respectively. The results of planned outages system reliability for the same feeders were also analyzed and presented.

Authors and Affiliations

Aibangbee, J. O. 1 ,, Ckukwuemeka, I. N. 2

Keywords

Related Articles

Empowering The 21st Century Building Technology Students Through Entrepreneurship Education

This study examined the role of Entrepreneur Education in empowering the 21st century students of Building Technology in Nigeria. It is observed that our country has a high rate of unemployment, low standard of living, a...

Overview of the Nigerian Power Sector

: The power sector in Nigeria through the years have been a tortuous, difficult, painful, devastating and herculean task for both the governments and the populace. A population of about 170 million people with more than...

Application of Retaining Wall in the Control of Flooding and Gully Erosion

This research concerned itself with the development of an approach which can be used in the reduction of perennial problems of flooding and gully erosion. It, however, applied the retaining wall as a technological means...

http://ajer.org/papers/v5(02)/F0502042048.pdf4D Collaborative Non-Local Means Based Diffusion MRI Denoising

Noise is a major issue that reduces the quality of images acquired by diffusion MRI (dMRI). Recently, the non-local means (NLM) algorithm has been proposed and successfully applied in dMRI denoising. However, NLM relies...

Design Of A Neural Network Controller To Enhance The Control Of Flights In Bad Weather Conditions

Adaptive control is a control method used by a controller which must be adaptable to the controlled system in relation to the parameters which may vary, or are initially uncertain. This is concerned with the control laws...

Download PDF file
  • EP ID EP401623
  • DOI -
  • Views 59
  • Downloads 0

How To Cite

Aibangbee, J. O. 1, , Ckukwuemeka, I. N. 2 (2017). Reliability Assessment of APO 132/33 KV Electric Transmission Substation Abuja. American journal of Engineering Research, 6(8), 170-176. https://europub.co.uk./articles/-A-401623