Reliability of blood gas analyzer for the measurement of electrolytes - A comparative study

Journal Title: International Journal of Clinical Biochemistry and Research - Year 2016, Vol 3, Issue 4

Abstract

Background: Electrolyte and blood gas analysis are essential for most patients who are admitted in the casualty. Routinely simultaneous arterial and venous sample would be sent to the laboratory for blood gas analysis and serum electrolytes respectively. Electrolytes can also be measured by the blood gas analyzer. We wanted to find out if these values were reliable. Methods: This study has been checked and permitted by the hospital ethics committee. We obtained two samples, one venous and one arterial sample from patients in the intensive care unit (ICU) and casualty of Ashwini rural medical college, hospital and research centre, (ARMCH&RC) Kumbhari Solapur. The arterial blood samples were analyzed on the ABOTT arterial blood gas analyzer (ABG) and venous samples were analyzed on PROLYTE electrolyte autoanalyzer (AA). Both instruments were placed in our biochemistry laboratory. Results: A total of 200 samples were analyzed. The mean ABG sodium value was 132.0 mmol/L (SD 9.82) and the mean AA sodium (Na+) was 135.7 mmol/L (SD 9.99). The mean AA sodium value was more than mean ABG sodium but statistically significant difference was not found (p=0.18). The mean ABG potassium (K+ ) value was 3.4 mmol/L (SD 0.68) and the mean AA potassium (K+) was 3.8 mmol/L (SD 0.79). The mean AA potassium value was more than mean ABG potassium and found statistically significant difference (p=0.02). Conclusion: We found that there was no significant difference in the sodium values measured by the ABG analyzer and the autoanalyzer. However, there was a significant difference in the potassium values measured by these instruments.

Authors and Affiliations

Dipti Basavaraj Sanakal, Sagar Chandrakant Mhetre, Ramesh S Patil, Abdul Kayyum Shaikh

Keywords

Related Articles

Serum cholesterol profile in children with celiac disease and effect of gluten free diet

Background: various researchers have shown association of celiac disease with altered lipid profile. We studied serum cholesterol levels in patient with celiac disease and effect of gluten free diet on it. This study aim...

Effect of Hypothyroidism on lipid profile

Objective: To study the effects of subclinical and overt hypothyroidism on serum levels of low density lipoprotein(LDL), total cholesterol(TC), high density lipoprotein (HDL) and triglycerides(TG). And also to compare th...

Lipid profile in Type 2 diabetes mellitus and in diabetic nephropathy

Introduction: Diabetes mellitus (DM) is characterized by abnormalities of carbohydrate, protein and fat metabolism due to absolute or relative deficiency of insulin secretion, accompanied by varying degrees of resistance...

Correlation of Serum C-peptide and Serum uric acid Levels with Glycated Hemoglobin in Patients of Type 2 Diabetes Mellitus

Background: Alterations in serum uric acid levels are associated with changes in Blood glucose. While impaired Glucose tolerance is accompanied with increased levels of Uric acid, the levels decrease once overt diabetes...

Serum neutrophil gelatinase-associated lipocalin as an early biomarker of acute kidney injury in subjects undergoing percutaneous transluminal coronary angiogram with normal EGFR

Introduction: Detecting AKI in a timely fashion with the current AKIN staging criteria is a challenge because the diagnosis of AKI is usually based on changes in serum creatinine (SCr) which is a poor marker of early ren...

Download PDF file
  • EP ID EP242967
  • DOI -
  • Views 84
  • Downloads 0

How To Cite

Dipti Basavaraj Sanakal, Sagar Chandrakant Mhetre, Ramesh S Patil, Abdul Kayyum Shaikh (2016). Reliability of blood gas analyzer for the measurement of electrolytes - A comparative study. International Journal of Clinical Biochemistry and Research, 3(4), 376-379. https://europub.co.uk./articles/-A-242967