Research of an electrical network elements models for automation of its management

Abstract

The scheme of the electric network, which includes the generator, the transformers, the electric transmission line, which includes the device of compensation, the complex equivalent load, which includes the asynchronous motor, the device of compensation, is considered. Mathematical modeling was carried out. The work of the scheme is considered in the mode of maximum load, and in the transition process. The algorithm of the electrical network estimation from the point of power losses minimization in steady-state regime, i.e. energy saving, and from the standpoint of the stability of the electrical network, is analyzed. The effectiveness of attracting existing technical measures to optimizing the distribution of power flows and providing optimal regimes is shown.

Authors and Affiliations

G. SHEINA

Keywords

Related Articles

Quasioptimal control of synchronous motor with permanent magnets using a strategy of "maximum torque per ampere"

For synchronous motors with built-in permanent magnet rotor was made a comparison control strategy "maximum torque per ampere (MTPA)" and the sample vector control algorithm with maintaining co...

Selection and development of neural network architecture for finding the maximum mechanical power of the propeller.

An example of using a neural network for finding the value of the point of maximum power in a power supply system with an alternative energy source (wind generator) is given in this work. The main feature of the built n...

Hybrid Multilevel Converter of medium voltage.

For the medium-voltage frequency converters are used: a cascade connection inverters (up to 10 kV) and three-level NPC inverters (up to 4.16 kV). ABB released a converter type ACS 2000 with active-neutral-point-clamp...

Use of the Fourie transform algorithm for improving phase to the earth fault protection in distribution electric networks.

New algorithms of selective protection against phase-to-earth faults in compensated power supply systems with a voltage of 6-35 kV are developed, in which, due to the influence of the Petersen coil, the selective action...

Efficiency of installation of turbo drive of the feed pump instead of electric drive for 200 MW power plants.

There are 43 power generating unit with the capacity of 200 MW operate in Ukraine. Some of them for various reasons work with incomplete load The reasons for this are low fuel quality, technical condition of the boiler...

Download PDF file
  • EP ID EP660354
  • DOI -
  • Views 190
  • Downloads 0

How To Cite

G. SHEINA (2018). Research of an electrical network elements models for automation of its management. Наукові праці Донецького Національного Технічного Університету серія: Електротехніка і Енергетика, 1(1), 12-16. https://europub.co.uk./articles/-A-660354