Review Of Experimental And Numerical Analysis Of Heat Exchanger In The Light Of Waste Heat Recovery Applications
Journal Title: International Journal of engineering Research and Applications - Year 2018, Vol 8, Issue 9
Abstract
The present work has been carried out with a review of the performance of a helical coil heat exchanger in the light of waste heat recovery applications. In maximum cases analysis was done for number of cases and the effect on temperature rise and the pressure drop in the helical tube and shell was observed by researchers. It was revealed that the empirical correlation is quite in agreement with the experimental results within experimental error limits. Based on the results obtained from the CFD and Experimental analysis, The NTU value of the helical coil has been reasonably low thereby justifying the name compact. The effectiveness of the helical tube heat exchanger is quite comparable with other conventional heat exchanger design
Authors and Affiliations
Mukesh Sharma, Jagdeesh Saini
Green Radio Technique for Energy Efficient Wireless Networks with Hybrid Solar Wind System
Nowadays the number of users and the use of telecommunication systems are increasing rapidly and this result in greater demands on energy usage. Based on the extensive Life-cycle assessment (LCA) conducted by various net...
ANFIS based Doubly Fed Induction Generator for WECS with LLCL-2TRP Filter
The wind energy conversion system integrated with a doubly fed induction generator. The PWM based back-toback power converters produced harmonic and as well as the non-linear loads are also a contributor of harmonics. Fi...
High Speed and Area Efficient Booth Multiplier Using SQRT CSLA with Zero Finding Logic
Addition is one of the common and widely used fundamental arithmetic operation in many VLSI systems. The critical elements in general purpose and digital-signal processing processors are High performance VLSI integer add...
Eco-Friendly And Solvent Free Synthesis Of Cerium Oxide Nano Particles Using Methacrylic Acid As Organic Dispersant. An Extended Application to the Removal of Orange G Dye.
Cerium oxide nanoparticles have been synthesized by microwave method using cerium nitrate and methacrylic acid as precursors. The material was structurally characterized by XRD and SEM and the optical characterization wa...
Integration of Finite Element Method with Runge – Kuta Solution Algorithm
Runge – Kuta (RK) method is reasonably simple and robust for numerical solution of differential equations but it requires an intelligent adaptive step-size routine; to achieve this, there is need to develop a good logica...