Role of Doppler Navigation in Minimally Invasive Procedures under Ultrasound Guidance
Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 13, Issue 2
Abstract
Aim: To highlight the possibilities of Doppler methods to optimize navigation and control of percutaneous echo-controlled minimally invasive interventions. Study Design: 25,543 diagnostic and therapeutic minimally invasive interventions were carried out on organs and tissues of different localizations. Place and Duration of Study: Department of Oncology and Radiology, M. Gorky Donetsk National Medical University, Ukraine. 25,543 diagnostic and therapeutic minimally invasive interventions (2004-2013). Methodology: Ten years of experience in carrying out percutaneous minimally invasive interventions under ultrasound guidance using Doppler modes. Fine needle aspiration and core needle biopsy, drainage, etc of different organs and tissues, effectiveness of optimization methods of visualization and analysis of results of their use in minimally invasive treatment of liver abscesses under US control, comparative analysis of main and control groups were carried out using student t-test and chi square - χ2. Ultrasound scanners used: Dornier AI 5200, Philips HDI 5000, Toshiba Aplio 500), probes - linear (7.5 MHz), convex (3.5-5.0 MHz). Paramount was the safety of minimally invasive procedure in visualizing instrument used. Results: It was established that optimal was the power Doppler mode for navigation in percutaneous interventions, prevent hemorrhagic complications, select a safe acoustic window, which improved the location of fluid motion in the hollow needle and visualization of the biopsy instrument based on initiation of twinkling artifact. The use of developed methods to improve ultrasound visualization in minimally invasive treatment of liver abscesses significantly reduced pain - 12.9%, avoided haemorrhage and leakage of pus into peritoneal cavity, reduced the number of inadequate drainages - 36.6%, reduced the duration of inpatient treatment - 2.2 times. Conclusion: It was established that use of power Doppler mode enhances the effectiveness and safety of percutaneous ultrasound-guided interventions. Thus, the studies confirmed the clinical use of optimization techniques of visualization in minimally invasive procedures under ultrasound guidance.
Authors and Affiliations
Wilson Josiah Iju, Zubov Alexander Dem'yanovich
Hepatitis B Virus Seropositivity among Schistosomiasis and Diabetes Mellitus Patients in Sana'a City, Yemen
Hepatitis B virus (HBV) infection is a major public health problem worldwide, often coexisting with other illnesses like parasitic infections and other chronic diseases. Data on the association of HBV infection with schi...
The Use of Canine Teeth in the Establishment of Sexual Dimorphism in the Madhya Pradesh (Mahakoushal Region) Population
Forensic odontology plays an important role in establishing sex, age, and race of unidentified persons. It involves proper handling and examination of dental evidence, thorough scientific specimen evaluation, and an accu...
Symptomatic Papillary Fibroelastoma- Case Report and Literature Review
Primary cardiac tumors represent a small subset of cardiac neoplasms. The papillary fibroelastoma (PFE) is a benign tumor that typically affects the cardiac valvular system and is second in prevalence only to myxomas. Th...
Effective Physical Therapy Treatment of Post-Cesarean Section Low Back Pain – Case Report
Introduction: Treatment of low back pain after cesarean section has been studied with exercise programs, but there has been little with a full physical therapy treatment plan involving manual therapy and therapeutic exer...
Effect of Different Primers on the Peel Bond Strength between Silicone Elastomer and Acrylic Resins
Introduction: Implant-supported extra-oral prostheses often require a retentive matrix to hold gold alloy clips and magnets, which act as retentive means. Silicone elastomers have a different structure to acrylic resins....