Room-temperature susceptometry predicts biopsy-determined hepatic iron in patients with elevated serum ferritin
Journal Title: Annals of Hepatology - Year 2012, Vol 11, Issue 1
Abstract
Background. There is an ongoing clinical need for novel methods to measure hepatic iron content (HIC) noninvasively. Both magnetic resonance imaging (MRI) and superconducting quantum interference device (SQUID) methods have previously shown promise for estimation of HIC, but these methods can be expensive and are not widely available. Room-temperature susceptometry (RTS) represents an inexpensive alternative and was previously found to be strongly correlated with HIC estimated by SQUID measurements among patients with transfusional iron overload related to thalassemia. Aim. The goal of the current study was to examine the relationship between RTS and biochemical HIC measured in liver biopsy specimens in a more varied patient cohort. Material and methods. Susceptometry was performed in a diverse group of patients with hyperferritinemia due to hereditary hemochromatosis (HHC) (n = 2), secondary iron overload (n = 3), nonalcoholic fatty liver disease (NAFLD) (n = 2), and chronic viral hepatitis (n = 3) within one month of liver biopsy in the absence of iron depletion therapy. Results. The correlation coefficient between HIC estimated by susceptometry and by biochemical iron measurement in liver tissue was 0.71 (p = 0.022). Variance between liver iron measurement and susceptometry measurement was primarily related to reliance on the patient’s body-mass index (BMI) to estimate the magnetic susceptibility of tissue overlying the liver. Conclusions. We believe RTS holds promise for noninvasive measurement of HIC. Improved measurement techniques, including more accurate overlayer correction, may further improve the accuracy of liver susceptometry in patients with liver disease.
Authors and Affiliations
Bryan Maliken, William Avrin, James Nelson, Jody Mooney, Sankaran Kumar, Kris Kowdley
Diagnostic accuracy of magnetic resonance elastography in liver transplant recipients: A pooled analysis
Background and aims. We conducted an individual participant data (IPD) pooled analysis on the diagnostic accuracy of magnetic resonance elastography (MRE) to detect fibrosis stage in liver transplant recipients. Materia...
Liver stiffness assessed by transient elastography in patients with β thalassaemia major
Rationale for the study. This cross-sectional multicenter study was conducted to investigate any difference in liver stiffness measurements (LSM), evaluated by transient elastography, between patients affected by β thal...
Bile salt export pump deficiency disease: two novel, late onset, ABCB11 mutations identified by next generation sequencing
Progressive familial intrahepatic cholestasis (PFIC) is a heterogeneous group of autosomal recessive cholestatic diseases of childhood and represents the main indication for liver transplantation at this age; PFIC2 invo...
Hepatic Hydrothorax
Hepatic hydrothorax (HH) is a pleural effusion that develops in a patient with cirrhosis and portal hypertension in the absence of cardiopulmonary disease. Although the development of HH remains incompletely understood,...
Noninvasive markers of fibrosis: key concepts for improving accuracy in daily clinical practice
Noninvasive markers of fibrosis have emerged as an alternative to the staging of fibrosis by means of liver biopsy. Apart from being noninvasive and thus lacking the adverse effects of liver biopsy, they offer some adva...