Secondary - Side Phase- Shift- Controlled ZVS Three Level DC/DC Converter Topology

Abstract

This paper presents a soft switching dc/dc converter with secondary - side phase shift control strategy is proposed to improve the conversion efficiency and minimize the primary switch voltage stress to half of the input voltage. The Zero Voltage Switching (ZVS) performance is achieved for both primary and secondary side devices to reduce the switching losses due to secondary side phase shift control scheme. The voltage stress of the primary switches is only half of the input voltage by employing the improved Three Level structure, which makes the low voltage rated power devices available to improve the circuit performance. This paper describes the main operational modes of the proposed converter as well as simulation results based on the MATLAB/SIMULINK software and also compares the switching losses of the proposed converter with and without Zero Voltage Switching scheme.

Authors and Affiliations

B. Tejaswi, E. Raghu Babu, J. Sivavara Prasad

Keywords

Related Articles

Privacy Preservation for Preventing Data OverCollection in Smart Phones using Mobile-Cloud Framework

Smart city is meant to be the key for next generation urbanization process. In smart city all kinds of user data are stored in electronic devices to make everything intelligent and efficient. A smart phone is the most w...

Vibration Control of Unsymmetrical RC Building Using Tuned Mass Damper

Vibrations are one of many environmental factors that act on building and potentially reduce their lifetime. Current trends in construction demand taller and lighter structures, which are also flexible and having quite...

A Review on Adaptive Filtering Techniques for Power Line Interference Removal from Biomedical Signals

The recorded signals tend to get contaminated with background noise and to extract the high-resolution ECG signals from them is a vital matter of exploration. The objective behind ECG signal enhancement is basically to...

Laboratory Evaluation of WMA with Zycotherm Warm Mix Additive

Warm mix asphalt (WMA) is a technology is allows significantly lowering the bituminous production and paving temperature of conventional Hot mix asphalt (HMA). The WMA is prepared by mixing chemical additives to convent...

Factors Influencing Voice Onset Time (VOT): Voice Recognition

In this paper we study the methods to evaluate the features which might estimate the closeness of acoustic signals. For measuring Voice onset time, we were considered 3 stop consonants in word- initial position and two...

Download PDF file
  • EP ID EP20003
  • DOI -
  • Views 290
  • Downloads 4

How To Cite

B. Tejaswi, E. Raghu Babu, J. Sivavara Prasad (2015). Secondary - Side Phase- Shift- Controlled ZVS Three Level DC/DC Converter Topology. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(3), -. https://europub.co.uk./articles/-A-20003