SELECTED ASPECTS OF THE STRUCTURAL ANALYSIS OF THE NORTH DOME IN THE "FOUR DOMES PAVILION"
Journal Title: Civil and Environmental Engineering Reports - Year 2015, Vol 2, Issue 17
Abstract
The subject of the paper is north dome of the Four Domes Pavilion in Wroclaw, which was erected according to the project by architect Hans Poelzig in 1913. The geometry of the dome (plan, rise, thickness) has an essential influence on the stress distribution in the structure and may be a crucial factor determining the cracking pattern. The results of the study of archival documents and numerical analysis indicate that there is a need for increasing the bearing capacity of the structure. After carrying out 3D FEM analysis, it was decided to apply strengthening technology based on the FRCM system with carbon and P.B.O. fibers on the surface and on the external ring of the dome.
Authors and Affiliations
Jerzy JASIEŃKO, Krzysztof RASZCZUK, Marta MOCZKO, Magdalena PIECHÓWKA-MIELNIK
AN EVALUATION OF THE USABILITY OF SLUDGE FROM THE MECHANICAL-BIOLOGICAL SEWAGE TRATMENT PLANT OF THE TOWN OF ZIELONA
The paper contains an evaluation of the possibilities of using sludge from the town of Zielona Góra in agriculture. The sludge under research demonstrated positive fertilizing properties. It has been found that because o...
EVALUATION OF THE EFFICIENCY OF USE OF AGGREGATES AND CHEMICAL COMPOUNDS FOR WINTER ROAD MAINTENANCE
The purpose of this article is to indicate the most effective chemical agents used for winter road maintenance. The research included the examination of melting speeds of snow and ice under various chemical agents, such...
LONG-TERM TRANSFORMATIONS OF THE KARKONOSZE TOWNS - ON THE EXAMPLE OF KARPACZ
Karkonosze Mountains localities have a long and rich history. Earlier the building development was unique atmosphere and character. We are most interested in contemporary design at the present time. Intensive constructio...
COD FRACTIONS - METHODS OF MEASUREMENT AND USE IN WASTEWATER TREATMENT TECHNOLOGY
The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in four municipal mechanical-biological sewage treatment plants and one industrial sewage...
INTERNAL ROT DETECTION WITH THE USE OF LOW-FREQUENCY FLAW DETECTOR
The issue of rot detection in standing timber or stocked wood is very important in forest management. Rot flaw detection used for that purpose is represented by invasive and non-invasive devices. Non-invasive devices are...