Selecting the number of frequencies for real time electroimpedancemetry of biological objects

Abstract

Introduction. Determining the sufficient number of frequencies for biological object impedance measuring is being researched. The presence of one or two object granularities is considered. Formulation of the problem. Often impedance measuring is conducted in a real time conditions. The number of frequencies directly influences measuring time. Existing studies of frequencies quantity were based on a coarse Krike and Morse impedance model. Research methods and the results analysis. This work offers method for calculating the sufficient number of impedance measuring freqencies for biological object, which contains one or two granularities. Conclusions. Sufficient number of frequencies for the object containing one or two granularities was evaluated. Also path for discovering the case three and more granularities was prompted.

Authors and Affiliations

G. Timoshenko

Keywords

Related Articles

Using the three-frequency bioimpedance measurement for inhomogeneous biological objects

Introduction. The possibility of using three-frequency bioimpedance to determine the structure of a biological object with two inhomogeneities are investigated. Formulation of the problem. The veracity of the determinati...

The pedagogical testing definitions

The detailed integrative definition of pedagogical testing concept is presented by authors in this work. This definition gives into decomposition on separate components which characterize testing as the pedagogical measu...

Analysis of Accuracy of Direct Digital Method of Correlative-Interferometric Direction Finding with Two-Dimensional Correlative Processing of Spatial Signal

The paper investigates the accuracy of the direct digital method of correlative-interferometric direction finding with reconstruction of spatial analytical signal in the aperture of linear antenna array. The main require...

Reducing irradiation human head by cellular phone antenna

Introduction. The paper proposed a method of reducing irradiation human head by cellular phone antenna. A method of solving this problem, called the compensation method. In this method, an additional radiator is placed b...

Electronically methods and facilities of lungs auscultation

Disadvantage of the traditional means of pulmonology are considered. Electroacoustic and biomechanical ways of registration breath sounds on chest surface are analyzed. The block diagram of the switch-modulation device f...