Shunt Active Power Filter for Remove Harmonics Using Conventional PI and Fuzzy Logic Controllers

Abstract

The widespread use of power electronics devices such as inverter, rectifier, and so on. in power systems causes severe problems linked to power quality. The widespread use of nonlinear single-phase power electronic devices in the low voltage side has increased harmonic pollution in power systems to the large extent. One such problem is the generation of current and voltage harmonics causing the distortion of load waveform, heating of equipment, voltage fluctuation, voltage dip, etc. This paper provides a detailed study of shunt active power filter under two current control strategies, namely, p–q and d–q; their comparative analyses are performed to determine which method is better than the other. In both methods, a reference current is generated for the filter, which compensates either the reactive power or the harmonic current component in a power system. In this work, a current controller, known as the harmonic current controller, is described, which is used to provide remedial gating sequence of the IGBT inverter and thus helps remove the harmonics component. For proper pulse generation, conventional PI controller and fuzzy logic controller are used in this paper. A comparison of both the controllers is conducted, which highlights the superiority of the fuzzy logic control scheme.

Authors and Affiliations

Mr. M. Yugandhar Naidu, Ms. Yp. Swapna, Dr. D. Obulesu

Keywords

Related Articles

Dendrite Growth Model at Bonded (001) GaAs Interface

A periodic GaAs wafer-bonded structure was used for nonlinear optical device. Results showed voids present at the bonded GaAs twin boundary. These voids were caused by natural topographical irregularities and surface con...

Efficient Anti-Jamming Technique Based on Detecting a Hopping Sequence of a Smart Jammer

Military wireless communications have always been involved in the improvement of secured tactical Communications. However, securing such networks on a battlefield is far from being simple since wireless jamming attack ca...

Voltage Sag and Swell compensation using DVR to enhance Power Quality

The quick developments in power electronic technology have made it possible to mitigate voltage disturbances in power grid. Among the voltage disturbances challenging the trade, the voltage sags are considered to be the...

Modelling Photovoltaic System Using Bond Graph Method: A Comparative Study

Bond Graphs (BG)are perceived as a promising possibility for modeling complex physical systems. This paper explores its potential by undertaking the analysis, modeling and design of a photovoltaic (PV) solar system. A mo...

Active and Reactive Power Control for Grid-Connected PV Systems Using Cascaded Multilevel Converters

Photovoltaic (PV) panels generator module is the widely used system solar generated powers are cascaded and connected to the grid with a constant AC supply .pv cell which gets subjected to various intensities of sun ligh...

Download PDF file
  • EP ID EP388766
  • DOI 10.9790/1676-1303024861.
  • Views 132
  • Downloads 0

How To Cite

Mr. M. Yugandhar Naidu, Ms. Yp. Swapna, Dr. D. Obulesu (2018). Shunt Active Power Filter for Remove Harmonics Using Conventional PI and Fuzzy Logic Controllers. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(3), 48-61. https://europub.co.uk./articles/-A-388766