Six sigma in clinical biochemistry: It matters, measure it
Journal Title: International Journal of Clinical Biochemistry and Research - Year 2017, Vol 4, Issue 3
Abstract
Introduction: Accurate test results are the core of healthcare system since physician's decisions mostly depends on the laboratory results. The evaluation of laboratory performance is critical to maintain accurate laboratory results. Nowadays six sigma is the newest version of total quality management. It is quantitative goal for process performance. We aimed to gauge our clinical biochemistry laboratory performance on sigma metrics. Materials and Method: Internal Quality control (QC) and proficiency testing data for 12 clinical chemistry analytes for two COBAS 400 Plus clinical biochemistry auto-analyzers were analyzed retrospectively over a period of 12 months from July 2012 to June 2013. For all 12 analytes the coefficient of variation was calculated for both the levels of IQC, percentage bias was calculated from EQAS. Process sigma was calculated using CV%, Percentage bias and TEa values of various parameters were taken from Clinical Laboratories Improvement Act (CLIA) guidelines. Results: Satisfactory sigma values (> 6) were derived for Alkaline Phosphatase, Aspartate aminotransferase, Alanine aminotransferase (L2), Triglycerides, Uric acid, Glucose (L2) signifying less stringent QC rules in an order to achieve high error detection and low false rejection. For parameters - Albumin, Alanine aminotransferase (L1), Total Cholesterol, Total Bilirubin, Glucose (L1), Total Protein the sigma values were found between 3 & 6, signifying more QC rules to be implemented. Urea and Creatinine analytes performed poorly on the sigma scale with sigma < 3, signifying needs improvement in these methods. No significant difference was found in both COBAS equipments in context to sigma value. Conclusion: Application of six sigma principles would significantly helps in improving IQC process as well provides the scientific basis for recommendation of amount of QC that is actually needed.
Authors and Affiliations
Kirankumar P. Chauhan, Jatin D Patel, Amit Trivedi
Pitfalls of currently practiced approach for teaching medical students: opinions & options
Introduction: During a didactic lecture, information is given to the students by the teacher, where students are passive listeners and the teacher is the narrator. Interaction between the students and the teacher, though...
Estimation of Adenosine deaminase and proteinase inhibitory activity and their correlation with tuberculous effusion and other pleural effusion cases
Introduction: Diagnosis of tuberculous effusion is difficult with the conventional, bacteriological, cytological and histopathological methods in our country. Adenosine deaminase, serum proteins, phospholipids show marke...
Methylenetetrahydro folatereductase enzyme polymorphism associated with hyperhomocysteinemia in patients with stroke
Cerebrovascular stroke is complex heterogeneous multifactorial disorder associated with number of risk factors, including diabetes mellitus,hypertension, tobacco smoking or chewing; etc. MethylenetetrahydroFolate reducta...
Serum Amyloid A Protein levels in Neonatal Sepsis
Introduction: Early diagnosis of Neonatal Sepsis continues to remain a significant global health challenge. The commonly studied biomarkers of sepsis include CRP, TNF-α, PCT, SAA and other acute-phase reactants, each hav...
Comparison of glucose levels using glucometer and GOD-POD Method in diabetic patients
Introduction: Glucometer is widely used at hospitals and homes as a first line tool to get an idea about the current blood glucose levels. Since glucometers are used for making important decisions, it is essential that t...