Osmotically controlled implants yield precise zero-order drug delivery kinetics and are utilized in a number of applications. The implants deliver drugs for extended periods (weeks to years) and exhibit good in vivo/in v...
Ophthalmic liposomes of ganciclovir (GCV) were prepared by the reverse phase evaporation method, and their ocular pharmacokinetics in albino rabbits were compared with those obtained after dosing with GCV solution. The i...
In this study, high-density arrays (576 microneedles on a 5 × 5-mm backplate, gifted by Bosch, Germany, Stuttgart) with a microneedle length of 200 μm were used (Fig. 1 )....
Inert matrix tablets (ferrous sulphate-Ferrogradumet®, Abbott Laboratories, Australia) were used as supplied. Each tablet contained 375 mg ± 5% of ferrous sulphate, which is approx...
EP ID EP681568
DOI 10.1208/s12248-008-9047-2
Views 98
Downloads 0
How To Cite
John W. A. Findlay (2008). Specificity and Accuracy Data for Ligand-binding Assays for Macromolecules Should be Interpreted with Caution. The AAPS Journal, 10(3),
-. https://europub.co.uk./articles/-A-681568
Sign In Europub
For faster login or register use your social account.
Critical Variables Associated with Nonbiodegradable Osmotically Controlled Implants
Osmotically controlled implants yield precise zero-order drug delivery kinetics and are utilized in a number of applications. The implants deliver drugs for extended periods (weeks to years) and exhibit good in vivo/in v...
Novel Endogenous Glycan Therapy for Retinal Diseases: Safety, In Vitro Stability, Ocular Pharmacokinetic Modeling, and Biodistribution
The online version of this article (doi:10.1208/s12248-014-9563-1) contains supplementary material, which is available to authorized users.
Preparation and ocular pharmacokinetics of ganciclovir liposomes
Ophthalmic liposomes of ganciclovir (GCV) were prepared by the reverse phase evaporation method, and their ocular pharmacokinetics in albino rabbits were compared with those obtained after dosing with GCV solution. The i...
Impact-Insertion Applicator Improves Reliability of Skin Penetration by Solid Microneedle Arrays
In this study, high-density arrays (576 microneedles on a 5 × 5-mm backplate, gifted by Bosch, Germany, Stuttgart) with a microneedle length of 200 μm were used (Fig. 1 )....
Microstructural Analysis of Porous Composite Materials: Dynamic Imaging of Drug Dissolution and Diffusion Through Porous Matrices
Inert matrix tablets (ferrous sulphate-Ferrogradumet®, Abbott Laboratories, Australia) were used as supplied. Each tablet contained 375 mg ± 5% of ferrous sulphate, which is approx...