Stability of Raft construct through Locking Compression Plate for depressed Tibial Plateau Fractures
Journal Title: Journal of Trauma and Orthopaedic Surgery - Year 2018, Vol 0, Issue 0
Abstract
Abstract Background: In spite of all the advances, tibial plateau fractures still pose a challenge to the orthopaedic surgeons due to the following reasons: presence of hinge joints at the knee and the ankle which allows no adjustment for rotatory deformity after fracture, occurrence of open fractures and higher rate of post-operative infection. The aim of surgical treatment of tibial plateau fractures is to restore congruent articular surfaces of the tibial condyles maintaining the mechanical axis and restoring ligamentous stability eventually can achieve functional painless and good range of motion in the knee joint. Materials and methods:Records of 53 knees in 38 men and 15 women aged 20 to 70 (mean, 37.9) years who underwent open reduction and internal fixation using a periarticular raft construct through a 3.5-mm locking plate without use of a bone graft or bone substitute for split-depression and depressed (>5 mm) proximal tibial plateau fractures (Schatzker type II and type III or AO/OTA type 41 B2 and B3). Out of the total 53 cases, 33 were of schaztkers type II while 20 cases were of type III who underwent the surgery between April 2016 and April 2018 at our institute were reviewed. Clinical and radiographic examinations were conducted in Follow-up at 1, 3 and 6 months. The Rasmussen radiological and clinical score, Lysholm knee score and Oxford knee score were assessed. Results: All patients achieved bone union after a mean of 12.87 (range, 8–24) weeks. The mean range of motion was 119.32º (range, 80º–135º). The Rasmussen radiological score was good to excellent in 48 cases while fair and poor outcome was seen in 4 and 1 cases respectively. The Rasmussen clinical score was good to excellent in 48 cases, while fair and poor outcome was seen in 4 and 1 cases respectively. As per Oxford Knee score, good to excellent outcome was obtained in 90.56% cases while fair and poor outcome was seen in 7.55% and 1.89% cases. As per Lysholm’s score, excellent and good outcome was obtained in 71.7% and 18.87% cases while fair and poor outcome was seen in 7.55% and 1.89% cases respectively. Conclusions:The stability of the internal fixation of proximal tibia fractures(Schatzker type II and type III or AO/OTA type 41 B2 and B3) after open reduction and internal fixation using a periarticular raft construct through a locking plate without use of a bone graft for split-depression tibial plateau fractures is a viable option
Sub-acromial spacer for Massive Rotator Cuff Tears- Biomechanical rationale and Review of Literature
Massive rotator cuff tears are a common cause of shoulder pain and functional disability in the elderly population. No consensus exists regarding management of massive irreparable tears of the shoulder. Conventional surg...
An Unusual swelling in Tibia: Osteochondroma in an Adult
Introduction: Osteochondroma is the most common benign tumor of skeletal system arising in a young child and growing during childhood to adolescence. Its growth ends when epiphyseal plate closes. Growth of an osteochondr...
Interlocking nails: Indian or imported? A study of 131 patients
Background: Currently, intramedullary nails used for displaced mid-shaft fractures of tibia and femur are either made locally or imported. For a majority of Indian patients, cost of imported implants could be a constrain...
Cost effectiveness of commercial vacuum-assisted closure (VAC) versus custom made vacuum-assisted closure (VAC)
Background: The initial management of open wounds is copious irrigation and thorough debridement, which can cause significant tissue defects. Definitive wound cover can only be planned once the wound is healthy and patie...
Functional Outcome of Arthroscopic Rotator Cuff Repair-A Clinical Study
Background: Rotator cuff tear is among the most common condition affecting shoulder. The spectrum ranges from inflammation to massive tear. The goal of repair is to eliminate pain and improve function. Arthroscopic rotat...