Abstract

Objective: To study the results in terms of functional and radiological outcome of distal radius fractures treated with volar locking compression plates using MIPO technique. Introduction: Minimally invasive procedures decrease surgical damage as well as the incidence of complications. They have their main indication in patients with marked soft tissue lesions. Small incisions, made away from the fracture site, help to minimize further soft tissue injury during surgical stabilization, and they preserve bone vascularity, contributing to bone union and fewer complications. They were first used to treat complex lower extremity metaphysodiaphyseal and periarticular fractures that could not be treated properly using intramedullary nails. Subsequently, its application was expanded to include upper extremity fractures, mainly humerusfractures, but little has been published about its use in distal radius fractures [3]. Methodology: A cohort of 20 cases of distal radius fractures treated with MIPO Technique using volar locking compression plates during Jan 2016 to Sep 2016. Results: Out of 20 patients, 13 excellent (65%), 6 good (30%) and 1 fair (5%) and no poor results were obtained using Modified Gartland and Werley’s scoring system.

Authors and Affiliations

Dr. Nirav Shukla, Dr. Hemant H Mathur, Dr. Parth J Patel, Dr. Gaurang M Patel, Dr. Sachin Sharma

Keywords

Related Articles

A prospective randomised controlled study in patients undergoing patelloplasty in total knee replacement with coagulation diathermy and without coagulation diathermy

Anterior knee pain in the patella femoral area after TKA has been addressed in a growing number of studies. Picetti et al. reported that anterior knee pain was present in 29% of the knees after TKA without patellar resur...

Selection of implant based on CT evaluation of trochanteric & subtrochanteric fractures

Background: CT scan evaluation of the morphology of trochanteric & subtrochanteric fractures helps in the selection of appropriate implant for fixation of proximal femoral fractures, resulting in better surgical outcome....

Arthroscopically assisted anterior cruciate ligament reconstruction: Comparison of bone-patellar tendon-bone versus semitendinosus gracilis autograft

Anterior cruciate ligament (ACL) tear is the most common serious ligamentous injury to the knee joint. The ACL is the primary stabilizer against anterior translation of the tibia on the femur and is important in countera...

Short same segment fixation of thoracolumbar fractures

Introduction: Thoracolumbar fractures are the most common injuries being treated by spine surgeons. Conventionally these fracture were treated with 2 levels above and 2 levels below the fracture site. The goal of interna...

A prospective study to analyse various methods of surgical fixation of metacarpal & phalangeal fractures

Introduction: Fractures of metacarpals and phalanges are among the most common injuries seen in emergency departments, constituting between 14% to 28% of all visits. Though large number of hand fractures can be treated c...

Download PDF file
  • EP ID EP499745
  • DOI 10.22271/ortho.2017.v3.i3h.88
  • Views 104
  • Downloads 0

How To Cite

Dr. Nirav Shukla, Dr. Hemant H Mathur, Dr. Parth J Patel, Dr. Gaurang M Patel, Dr. Sachin Sharma (2017). Study of distal radius fracture treated with minimally invasive plate osteosynthesis technique. International Journal of Orthopaedics Sciences, 3(3), 547-550. https://europub.co.uk./articles/-A-499745