Study of L-Glutamic Acid in Solid State for its Possible Use as a Gamma Dosimeter at Different Temperatures (77, 195 and 295 K)

Abstract

The experimental response of the dosimeter as a function of the irradiation temperature plays an important role, and this effect has consequences in the practical applications of dosimetry. In this work, L-glutamic acid (2-aminopentanedioic acid) is proposed to be a good response, easy to handle, and a cheap gamma dosimeter. For this purpose, polycrystalline samples were irradiated with gamma rays at 77, 195, and 295 K and doses in the kiloGray range (43–230 kGy). The potential use of the glutamic acid system as a chemical dosimeter is based on the formation of stable free radicals when the amino acid is exposed to ionizing radiation. The observed species in these experiments were attributed to deamination and decarboxylation reactions that were studied using electron spin resonance (ESR). The results indicate that the analysis generates a linear response as the irradiation dose increases in a reliable range for industrial and research purposes at three different temperatures.

Authors and Affiliations

A. L. Meléndez-López, J. Cruz-Castañeda, A Paredes-Arriaga, S Ramos-Bernal

Keywords

Related Articles

Spontaneous CP Violation Jarlskog Invariant in SM⊗S3

In our days, CP (Charge Parity) violation in the Standard Model of fundamental interactions still remains as an open problem. It is well known that explicit CP violation may be included by imposing complex Yukawa couplin...

Characterization of LR-115 Type 2 Detectors for Monitoring Indoor Radon 222: Determination of the Calibration Factor

The city of Lima, capital of Peru, has about 11 million inhabitants. Lima has no records about the indoor Radon 222 concentration levels in dwellings. Hereby, we are planning to register the indoor radon concentrations i...

Nuclear Tracks Morphology Study Using Raman Methodology

In this work, a new methodology for rendering profiles of etched nuclear tracks is presented, using confocal micro-Raman spectrometry instrumentation. The precise profile of etched nuclear tracks with normal and/ or angu...

Binary Fission fragmentation of 184 466,476X

Based on the statistical theory of fission, we discuss here the binary fission fragmentation of these giant nuclear systems formed in low energy U + U collisions. Here, the mass and charge distribution of fragments from...

Proposal of a Novel Setup for Linac Monitoring Using a Specifically Designed Plastic Scintillator and a Spectrophotometer

In this work, we report the design, implementation, and results of an alternative monitoring system for a linear accelerator (LINAC) used in medical therapy. The system proposed consist in as lab of scintillator plastic...

Download PDF file
  • EP ID EP595533
  • DOI 10.15415/jnp.2017.51017
  • Views 229
  • Downloads 0

How To Cite

A. L. Meléndez-López, J. Cruz-Castañeda, A Paredes-Arriaga, S Ramos-Bernal (2017). Study of L-Glutamic Acid in Solid State for its Possible Use as a Gamma Dosimeter at Different Temperatures (77, 195 and 295 K). Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 5(1), 179-186. https://europub.co.uk./articles/-A-595533