Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2016, Vol 40, Issue 40

Abstract

The reactive power flows affect voltages, losses and transmission capacities. Thus MVAR flows are a matter of increasing concern for the grid operators and the Romanian Regulatory Authority for Energy has established their importance into a specific Order. The latest corresponding regulation for Romania allows the grid operator to exonerate of payment those injections of reactive which affect in a positive manner positively the voltages in the network. Such exemption is difficult to apply since the influence of MVARs on voltages is locational and time dependent. This paper deals with the assessment of reactive powers related to network users for payment and compensation purposes. The drawbacks are evaluated and compared with the benefits for voltage regulation, according to Romanian regulations. Theoretical skills are combined into one organic methodology, and an in-house software package for reactive power assessment is built. This is based on sensitivities of voltage, loss and transmission capacity to reactive injections into nodes. A case study consisting of a real 110kV network of about 2000 nodes was adopted. The survey was conducted for 6000 hours and outlines voltage to sink’s MVARs. The results were used to evaluate the opportunities to compensate and/or to discharge payments the MVARs with positive contribution to voltage regulation. This paper proposes a sensitivity based analysis for a real 110kV network.

Authors and Affiliations

Leonardo Geo Manescu, Denisa Rusinaru, Marian Ciontu, MIron Alba

Keywords

Related Articles

Simulation of Idle Running Operating Characteristics for Low-Power Asynchronous Motors

The opportunity of this work is backed by the possibility to predetermine the operating characteristics of an asynchronous motor in idle running. This contributes to the realization of a high performance electric drive....

 Designing a Simultaneous Control of Several Motors with a VHL Programming Language for a Single Microcontroller

 The paper is focused, mainly, on the timing design for the simultaneous digital control of several electrical motors using a very high level programming language (under an Integrated Development Environment – IDE)...

Evaluating RMS of Linearly Variable Magnitude Waveforms by Using FFT and WPT. Theory and Practice

The paper deals with the evaluation of the Root Mean Square (RMS) indices of signals with linearly variable magnitude by using Wavelet Packet Transform (WPT) and Fast Fourier Transform (FFT). Firstly there is presented a...

OPTOELECTRONIC CURRENT TRANSFORMER FOR MEDIUM VOLTAGE NETWORKS

The paper presents an optoelectronic hybrid current transformer which allows current measurement in medium voltage networks and provides remote measuring signal transmission with high immunity against disturbances. An...

SINGLE-SPOOL JET ENGINE FOR AIRCRAFT WITH AFTERBURNING SYSTEM

This paper deals with a single-spool single jet engine with afterburner for thrust augmentation. The afterburning system consists of a special combustor with its own fuel pump, turned round by the engine’s spool and oper...

Download PDF file
  • EP ID EP262627
  • DOI -
  • Views 105
  • Downloads 0

How To Cite

Leonardo Geo Manescu, Denisa Rusinaru, Marian Ciontu, MIron Alba (2016). Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 40(40), 25-32. https://europub.co.uk./articles/-A-262627