Study Of Variations In Anatomy And Intramedullary Canal Diameter Of Clavicular Bone In Indian Population

Abstract

Background and objective Although the length and shape of the clavicle are well understood, the dimensions of the medullary canal although available for other long bones have not been clearly defined for clavicle. The variability of the curvatures of the clavicle are also not well understood among the Indian population.These parameters have great importance when considering intramedullary nailing techniques. Materials and methods 100 cadaveric clavicles of both sexes were analysed. Results The mean medial end diameter in male right clavicles in Antero posterior and Supero inferior planes were 17mm and 16.5mm respectively. In male left clavicles it was 15.5mm and 16.25mm respectively. In female right clavicles it was13.9mm and12.6mm respectively.In female left clavicles it was 14.75mm and 12.7mm respectively. The mean middle 3rd diameter in male right clavicles in AP and SI planes are 7.5mm and 5.8mm respectively. In male left clavicles it was 6.25mm and 6mm respectively. In female right clavicles it was 5.5mm and 5.7mm respectively.In female left clavicles it was 5mm and 4.6mm respectively. The mean isthmus medullary canal diameter in male right clavicles in AP and SI planes were 5.1mm and 5.6mm respectively. In male left clavicles it was 4.45mm and 5.9mm respectively. In female right clavicles it was 4.25mm and 4.8mm respectively. In female left clavicles it was 4.25mm and 4.75mm respectively.The overall average of male and female clavicles in AP plane was 4.45 mm. The mean lateral end medullary canal diameter in male right clavicles in AP and SI planes were 7.1mm and 19.4mm respectively. In male left clavicles it was 5.9mm and 17mm respectively. In female right clavicles it was 5.45mm and 16.9mm respectively. In female left clavicles it was 4.9mm and 15.25mm respectively. Conclusion The narrow point is the location of isthmus in majority of the clavicle fractures, which adds considerable difficulties for intramedullary fixation.The AP diameter at the isthmus is the narrowest part of the medullary canal and this has been not addressed in any literature to our knowledge. This gains importance in the Intramedullary nailing and future nail designs for clavicle fracture fixation.

Authors and Affiliations

T M Manohar, L Kumar, O Obulivijayshankar

Keywords

Related Articles

Intertrochanteric Fracture Management Proximal Femoral Nailing Vs Dynamic Hip Screw

Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered...

Outcome Of Intraarticular Distal Radius Fracture In Adults Treated By Open Reduction And Internal Fixation With Volar Buttress Plate

Background: Distal radius fracture with intra-articular extension (AO Type C1, C2 and C3) is a major cause of severe morbidity in patients with upper extremity injuries. Aims: The purpose of this study was to evaluate...

Pattern Of Open Tibial Shaft Fractures In Vindhya Region Of Madhya Pradesh

Introduction: Tibia is the most commonly fractured long bone from its shaft. Open Fractures are particularly common in tibia because of its subcutaneous location. Even small degrees of rotational mal-alignment of the fra...

Functional Outcome Of Distal Tibia Giant Cell Tumour

This is a prospective study of the functional outcomes of Giant cell tumor of tibia. Giant cell tumor of bone (GCTB) is an intermediate, locally aggressive but rarely metastasizing tumor. A total of 6 patients were studi...

Radiological Evaluation Of Fracture Neck Of Femur Treated With Cannulated Screw (CCS) Fixation With Respect To Union And Avascular Necrosis Of Femoral Head

Background of the study-The neck of femur fractures in young population is associated with high energy trauma. Osteosynthesis with Cannulated Cancellous Screws (CCS) is a described technique and helps in preserving head...

Download PDF file
  • EP ID EP394835
  • DOI -
  • Views 114
  • Downloads 0

How To Cite

T M Manohar, L Kumar, O Obulivijayshankar (2017). Study Of Variations In Anatomy And Intramedullary Canal Diameter Of Clavicular Bone In Indian Population. International Journal of Orthopaedics Traumatology & Surgical Sciences, 3(1), 469-473. https://europub.co.uk./articles/-A-394835