Surface wear of All Zicronia, All PEEK and Zirconia-Peek Telescopic Attachments for Two Implants Retained Mandibular Complete Overdentures. In -Vitro study using scanning electron microscope.

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2019, Vol 18, Issue 2

Abstract

Purpose: This study aimed to investigate and compare wear of telescopic attachments constructed from different tooth colored materials by evaluating surface changes of both primary and secondary copings using Scanning Electron Microscope (SEM). Materials and methods: Three identical clear acrylic resin models of completely edentulous mandibular arch were fabricated for this study. Two implants were installed bilaterally in canine region of the models by the aid of guide template. The models were scanned to design resilient telescopic attachment using CAD/CAM technology on the 3D image of the model. According to the material used to fabricate the telescopic attachment, the models were categorized as follows: 1-st group (PP) whereprimary and secondary telescopic copingswere constructed from peek, 2-nd group (ZZ) where primary and secondary telescopic copings were constructed from zirconia, 3-rd group (ZP) where the primary copings were made from zirconia and secondary ones were made from PEEK. Three identical mandibular complete overdentures were constructed. The secondary telescopic copings of each group were picked up in the overdenture fitting surface. Surface changes of primary and secondary copings were evaluatedusing scanning electron microscope (SEM) at time of secondary copings pickup (T0) and after simulation of 6 monthsofoverdenture use (T6). Results: Significant wear was shown within each group between T0 and T6 and between groups in both primary and secondary coping where the highest wear values were found in ZP group followed by PP and ZZ groups respectively. Conclusions: With respect to limitations of this study, it could be concluded that:Combining PEEK and Zro2 materials for telescopic attachment construction may be associated with more changes in surface topography in contrast to all PEEK or all zircon telescopic attachments.

Authors and Affiliations

Radwa M. K. Emera, Mohamed Elgamal, Mona M. Albadwei

Keywords

Related Articles

Misbeliefs and Preconceptions Regarding P- Value

The medical journals are abounding with „P values‟ and „tests of hypotheses. It is a common practice among medical researchers to quote whether the „test of hypothesis‟ they carried out is significant or nonsignificant a...

Clinical And Radiological Evaluation of Fully Hydroxyapatite Coated Uncemented Stems in Hip Arthroplasty

To assess the functional and radiological outcome of fully hydroxyapatite coated stems in hip arthroplasty. Prospective and retrospective study. Follow up 6wks,3mths,6mths,1year & then yearly. Minimum follow up of 6 mont...

Study of Cytology and Histopathology of Secondary Deposits in Lymph Node

Aim: To assess the reliable of cytological diagnosis of second deposits of Lymph node in compare with histopothology. Material And Methods: In a 3 year period 54 cases of secondary deposits of lymph nodes in cytology wer...

Pre-operative Apache II score as a tool to predict outcome in patients with gastrointestinal perforation at RIMS, Ranchi.

Background: Perforation peritonitis is one of the most commonly encountered surgical emergencies by a resident surgeon. Many scoring systems have been used to predict the mortality and the outcome of the patients present...

Study of Serum Cholinesterase, Lipid Profile and Serum Proteins in Nephrotic Syndrome

Background: Nephrotic syndrome is most commonly occurring problem in childhood and others. It is highly morbid even though many advances has evolved. Aim: To study the changes of serum proteins and serum cholinesterase i...

Download PDF file
  • EP ID EP467575
  • DOI 10.9790/0853-1802095968.
  • Views 65
  • Downloads 0

How To Cite

Radwa M. K. Emera, Mohamed Elgamal, Mona M. Albadwei (2019). Surface wear of All Zicronia, All PEEK and Zirconia-Peek Telescopic Attachments for Two Implants Retained Mandibular Complete Overdentures. In -Vitro study using scanning electron microscope.. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 18(2), 59-68. https://europub.co.uk./articles/-A-467575