Suspected hemolysis caused by type A therapeutic plasma exchange in a patient with AB subtype miss detected

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 5

Abstract

Objective To investigate the serological changes of blood type and whether hemolytic reactions occurred in a patient with ABw subtype after type A therapeutic plasma exchange(TPE) retrospectively. Methods The ABO blood group identification and genotyping was carried out by microcolumn gel method, microcolumn glass bead method, saline tube method and absorption-elution test, and the laboratory results before and after TPE were analyzed. Results The patient underwent 2 000 mL type A TPE in other hospitals and was transferred to our hospital. On the second day of hospitalization, the test showed consistency between forward and reverse blood typing. On the third day, the detection showed that Bc was ±~1+ , and discrepancy was found between forward and reverse typing. The presence of B antigen was confirmed through tube method and human anti-B absorption-elution test, and was identified as ABw03 by molecular biological method. After type A TPE, Hb and Plt both temporarily decreased, creatinine slightly increased, ALT and AST continued to decrease, while TBIL, DBIL and IBIL showed a temporary decrease followed by an increase, indicating a slight hemolytic reaction. Conclusion Infusion of large volume of plasma may cause hemolytic reactions when ABO subtype patients contain weak A or B antigens.The blood type should be strictly identified according to the ABO blood type forward and reverse typing standards. Additional laboratory tests combined with molecular biology techniques are required for weak agglutination, which can reduce the missed detection of ABO subtypes and reduce the occurrence of transfusion reactions.

Authors and Affiliations

Yanjing HE, Chang GAO, Qiushi WANG

Keywords

Related Articles

Matrix effect on the determination of Potency in Recombinant Coagulation Factor Ⅷ for injection

Objective To investigate the matrix effect on the determination of potency in Recombinant Human Coagulation Factor Ⅷ for Injection (rFⅧ). Methods Two different detection matrices were used to establish two methods for de...

Characteristics of lapsed apheresis donors from 2016 to 2020, Zhejiang Blood Center

Objective To understand the structural characteristics of lapsed apheresis donors in our blood center and provide guidance for further improving recruitment and retention strategies by retrospectively analyzing the chara...

HIV antiretroviral therapy among blood donors: the impact on blood safety

Objective To explore the the potential risks of antiretroviral therapy(ART) drugs on blood safety among blood donors in Shenzhen. Methods High pressure liquid chromatography coupled with tandem mass spectrometry (HPLC-MS...

Thromboelastography and routine coagulation tests in the management of coagulation during ECMO therapy: a comparative study

Objective To investigate the correlation and consistency between the parameters of thromboelastography(TEG) and routine coagulation tests, and to evaluate the application value of the two methods in heparin anticoagulati...

The clinical outcomes of elderly acute leukemia patients receiving allogenic hematopoietic stem cell transplantation and application of comprehensive nursing care

Objective To investigate the clinical outcomes of allogeneic hematopoietic stem cell transplantation in elderly patients with acute leukemia and the role of comprehensive nursing. Methods The data of 52 elderly patients...

Download PDF file
  • EP ID EP738813
  • DOI 10.13303/j.cjbt.issn.1004-549x.2024.05.004
  • Views 41
  • Downloads 0

How To Cite

Yanjing HE, Chang GAO, Qiushi WANG (2024). Suspected hemolysis caused by type A therapeutic plasma exchange in a patient with AB subtype miss detected. Chinese Journal of Blood Transfusion, 37(5), -. https://europub.co.uk./articles/-A-738813