The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations
Journal Title: Meandros Medical and Dental Journal - Year 2020, Vol 21, Issue 2
Abstract
Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH, Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex locators (EALs) with regard to detecting root perforations in dry conditions and in the presence of irrigation solutions [2.5% sodium hypochlorite (NaOCl), 17% ethylenediaminetetraacetic acid (EDTA) and Qmix]. Materials and Methods: Twenty single-rooted human teeth were perforated artificially with a 1 mm diameter in the middle region. The actual canal lengths up to the perforation site were determined, and then the teeth were embedded in an alginate mold. The electronic measurements of the perforations were obtained using a size #20 K-file for each EAL in various conditions. Results: There were significant differences between the different canal conditions in the Raypex 6 group (p<0.05), but no significant differences in the Root ZX mini group (p>0.05). There was a statistically significant difference (p<0.05) between the two EALs in the presence of EDTA solution, but no statistically significant difference between the accuracy of two EALs in the presence of other solutions and in the dry canal condition (p>0.05). Conclusion: Under the conditions of this study, both apex locators detected root canal perforations within a clinically acceptable (range of -0.18 to 0.31mm) distance from the coronal border of the perforation region. Irrigation solutions within the root canal affected the accuracy of Raypex 6, but not of Root ZX mini.
Authors and Affiliations
Zeliha Uğur Aydın, Demet Altunbaş, Büşra Meşeci
Evaluation of Water Sorption-solubility and Surface Roughness of Different Bulk Fill Composite Resins
Objective: This study aimed to investigate and compare the water sorption (WS), solubility (SO) and surface roughness (SR) of four bulk fill resin-based composites (RBCs), a conventional flowable RBC and a conventional h...
Effects of Melatonin at Different Doses on Experimental Epilepsy Model Induced By Pentylenetetrazole
Objective: This study aimed to evaluate the effect of melatonin (MEL) treatment on rats with experimental epilepsy induced by pentylenetetrazole (PTZ). Changes in the control, epilepsy and two treatment groups (25 mg/kg...
Effect of Non-cadaveric Methods on the Anatomy Education of Medical Students
Objective: Recently, with the inability to conduct face-to-face training due to the increasing cases of pandemic diseases such as the coronavirus disease-2019, the importance of digital applications in practical anatomy...
Clinical and Ultrasonographic Evaluation of Masticatory Muscles in Young Subjects with and Without Bruxism
Objective: This study aimed to evaluate the stress levels and alterations in temporomandibular joint (TMJ) and masticatory muscle thickness determined by ultrasonography (USG) in young individuals with and without bruxis...
Micro-shear Bond Strength of Aged Resin Composite Repaired with Different Universal Adhesives
Objective: This study evaluated the effect of two different universal adhesives on the repair bond strength of aged resin composite. Materials and Methods: Forty-four composite resin disks were prepared (5 mm x 3 mm)....