Abstract

Aim Ventilator circuits consist of inspiratory and expiratory tubing and disposable humidifier / bacterial filtre. Today’s disposable humidifiers are both disposable and has bacterial filtre. In this study, we aimed to determine the time of the efficiency of these humidifier / bacterial filtre in avoiding the ventilator circuit bacterial contamination. Material and Methods 32 patients who were mechanically ventilated at least 48 hours were included in this study. Sterile inspiratory and expiratory tubing with humidifier/ bacteriel filtre used in ventilator circuit and specimens were obtained from the endotracheal tube side and ventilator side of the humidifier/bacterial filters, water-traps and expiratory tubing side of the ventilator filter at 48th, 72 hours. Results At 48th and 72 hour, bacterial colonizations were noted at the endotracheal tube side of the filtres and tracheal aspirate materials and no bacterial colonization were seen at the ventilator side of the humidifier/bacteriel filtres, water traps and at the expiratory tubing side of the ventilator filtres. Conclusions Humidifier/bacteriel filtres those efficiency has been shown 72 hours in avoiding the ventilator circuit bacterial contamination. We think that; with additional study results, routine humidifier/bacteriel filtres changes can be done 72 hours. 

Authors and Affiliations

Güldem Turan, Asuman Şengöz İnan, Nur Akgün, Jale Taşçıoğlu, Paşa Göktaş

Keywords

Related Articles

Histerektomiden Sonra Gelişen Postkoital Transvajinal Evisserasyon: Olgu Sunumu

Transvajinal evisserasyon(TVE) çoğunlukla postmenapozal ve vajinal cerrahi geçiren olgularda görülmektedir. Premenapozal olgularda ise histerektomi sonrası postkoital oluşmaktadır. İki ay önce total abdominal histerekt...

Bingöl Yöresinde Çocuk Hastalarda Escherichia Coli Direnci 

Amaç: Bu çalışmada E.coli ile oluşan idrar yolu enfeksiyonunda antibiyotik direncini ortaya koymak amaçlanmıştır. Gereç ve Yöntem: 2007-2011 yılları arasında Bingöl Devlet Hastanesine idrar yolu enfeksiyonu şüphesi b...

The Comparison α-Blocker+M3 Selective Anti-Muscarinic Combined Therapy and α-Blocker Monotherapy

Aim: Effectiveness and reliability comparison of alpha-blocker monotherapy (doksazosin) and combined alpha-blocker+M3 selective antimuscarinic (doksazosin+darifenacin) treatments on male patients with Benign prostate...

Spontan İntrakapsüler Tonsiller Kanama 

Bu vaka sunumunda sol tonsilla palatina medialine yerleşen ve bir kök ile tonsil dokusuna tutunan bir tümör görünümünde olan spontan intakapsüler tonsiller kanama vakasını tartıştık. Hasta 30 yaşında sağlıklı bir gebe ka...

Melanosis Coli: Case Report 

Melanosis coli is a common condition characterized by dark pigmentation of colonic mucosa. Melanosis coli is thought to be a benign lesion that emerging related with the overuse of the anthraquinone containing laxative...

Download PDF file
  • EP ID EP114164
  • DOI 10.4328/JCAM.353
  • Views 141
  • Downloads 0

How To Cite

Güldem Turan, Asuman Şengöz İnan, Nur Akgün, Jale Taşçıoğlu, Paşa Göktaş (2011). The Effective Usage Time of the Humidifier/ Bactriel Filters in the Mechanical Ventilator Circuits . Journal of Clinical and Analytical Medicine, 2(3), 46-48. https://europub.co.uk./articles/-A-114164