THE EVALUATION OF POSSIBILITY OF NORMAL OPERATION OF CABLES BASED ON TWISTED PAIRS WITH PVC JACKET UNDER THE CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE
Journal Title: Електротехніка і Електромеханіка - Year 2017, Vol 0, Issue 5
Abstract
Introduction. Development of cables for structured cabling systems based on twisted pairs for shipbuilding is carried out in two main directions: increasing the fire safety of cables and increasing the long-term permissible operating temperature by using new, more heat-resistant, electrical insulating materials. Purpose. Substantiation of the possibility of unshielded cables on the basis of unshielded twisted pairs with thermoplastic polyethylene insulation in PVC protective jacket in conditions of high humidity and high operating temperatures on the basis of the results of accelerated aging. Methodology. The cycle of aging under conditions of increased humidity is performed for 336 hours. Then the sample was under natural drying conditions for 1440 hours. Thermal aging in a thermostat at 90 °C was carried out in two stages: first – for 206 hours, the second – for 260 hours. In the initial state and after accelerated aging, measurements of the capacitance and tangent of the dielectric loss angle of all the insulating gaps at frequencies of 100 Hz, 1 and 10 kHz were performed. Results. According to the results of accelerated aging under conditions of high humidity and temperature, it is established that the design of an unshielded cable based on unshielded twisted pairs with thermoplastic polyethylene insulation in a protective coating based on PVC-plastic is resistant to external influencing factors. Practical value. The prolonged holding at temperature of 90 °C is equivalent to operation at temperature of 40 °C for 6.8 years. At higher operating temperatures, the lifetime of the cable is significantly reduced.
Authors and Affiliations
G. V. Bezprozvannych, I. A. Mirchuk
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most pro...
APPROXIMATE CALCULATION OF ACTIVE RESISTANCE AND TEMPERATURE OF THE PULSE ELECTRIC ARC CHANNEL IN A HIGH-CURRENT DISCHARGE CIRCUIT OF A POWERFUL HIGH-VOLTAGE CAPACITOR ENERGY STORAGE
Purpose. To obtain calculation correlations for active resistance Rce and maximal temperature Tme of plasma channel of pulse electric arc in the air double-electrode system (DES) with metal (graphite) electrodes, and als...
AVERAGE GEOMETRICAL FEATURES OF THE ELECTRON WAVE PACKAGES DISTRIBUTION IN METALLIC CONDUCTORS WITH PULSED AXIAL CURRENT OF HIGH DENSITY
Purpose. Calculation and experimental determination of average geometrical features of distributing of macroscopic electron wave packages (EWP) in round cylindrical metallic conductors with the pulsed axial current of hi...
MODELING OF DYNAMIC CHARACTERISTICS OF A NONLINEAR OSCILLATORY SYSTEM WITH A MAGNETIC SPRING. PART 1
A passive magnetic vibration isolator (a magnetic spring) with cylindrical magnets is considered. A mathematical model is developed to calculate magnetic spring magnetic field and force. Numerical calculation of the vibr...
STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS
The study tested the process of the magnetic field (MF) mitigation in the HV three-phase power cable lines (CL) made of single core cables in two-ends bonding of their shields. Developed the technique of numerical simula...