The influence of the DLC and DLC-Si coatings on the changes occurring on the implants surface during the implant-bone contact

Journal Title: Engineering of Biomaterials / Inżynieria Biomateriałów - Year 2016, Vol 19, Issue 137

Abstract

In this study the DLC and Si-incorporated DLC layers were deposited on stainless steel alloy (AISI 316 LVM) using modified radio frequency plasma assisted chemical vapour deposition (RF PACVD) method and examined in terms of chemical, mechanical and tribological properties. The carbon layers were synthesized on two types of samples: flat cylindrical probes and the orthopaedic screws (both were made from AISI 316 LVM). In order to determine the chemical composition, morphology and structure of the manufactured coatings the XPS, AFM, SEM observation and EDS analysis were performed. Mechanical properties were measured using nanoindentation technique, as well as the tribological properties were performed using ball-on-disc tests. The obtained results were correlated with the biological response of the coatings. The influence of changes of the modified implants surface was evaluated using screwing/unscrewing test. The samples after conducted tests were controlled using microscopic observation (SEM) and qualitative analysis of the chemical composition on the surface of the screws (EDS). Results demonstrate that on the surface of the DLC and DLC-Si coatings the tribofilm made from mineral bone compounds was created.

Authors and Affiliations

L. Świątek, A. Olejnik, J. Grabarczyk

Keywords

Related Articles

Influence of environmental factors on contact lenses properties

Nowadays contact lenses are a very common way of vision correction. To be used successfully, they must meet a number of conditions. This article describes studies on the influence of environmental factors such as low tem...

Badania in vitro aktywności przeciwbakteryjnej bioszkieł zawierających Mg, Sr i Au wytworzonych metodą zol-żel

Celem prowadzonych badań było określenie aktywności przeciwbakteryjnej in vitro bioaktywnych szkieł dotowanych Mg, Sr i Au. Przedstawiono badania zmodyfikowanych bioszkieł zawierających wybrane pierwiastki wprowadzone dl...

The influence of collagen from various sources on skin parameters

Collagen is the main component of connective tissue – it represents 30% of total proteins in the animal body. This protein occurs in a wide range of tissues, e.g. in bone, skin, tendon, ligaments and cornea. It provides...

Micro-CT analysis of molar teeth restored by combining conventional and glass fibre reinforced composites

The loss of mineralized tissues of the tooth as a result of pathogenic processes and treatment is the principal factor leading to tooth weakening. Most frequently, the cracks occur on the filling surface as a result of r...

Electrochemical study of uncemented hip endoprosthesis cups

The aim of the research was to compare the properties of the new cup and the cup after alloplastic revision surgery which has been staying in the human body for 68 months. In the studies chemical composition, mechanical...

Download PDF file
  • EP ID EP559759
  • DOI -
  • Views 48
  • Downloads 0

How To Cite

L. Świątek, A. Olejnik, J. Grabarczyk (2016). The influence of the DLC and DLC-Si coatings on the changes occurring on the implants surface during the implant-bone contact. Engineering of Biomaterials / Inżynieria Biomateriałów, 19(137), 2-12. https://europub.co.uk./articles/-A-559759