The measurement of photoneutron dose around an 18 MV Varian linear accelerator by TLD600 and TLD700 dosimeters inside the polyethylene sphere of neutron probe LB 6411

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 6, Issue 1

Abstract

Bremsstrahlung X-rays from high-energy linear accelerators (Linacs) produce neutrons as a result ofphotonuclear reactions mainly with the different materials constituting the accelerator head. The neutronsproduced during high energy radiotherapy should be considered in terms of protection and ose escalation. Due to the very intense photon component in the Linac field causing pulse pile-up and dead-time effects indetectors, measurement of the corresponding neutron dose by active dosimeters is extremely troublesome. In this study, the neutron probe LB 6411, which active detector of 3He proportional counter tube was replaced withthe passive detectors of TLD600 and TLD700, has been used to perform neutron measurements at four pointsaround the 18 MV Varian 2100C Linac facility. The neutron dose equivalent at the distance of 1 and 2 m fromthe isocentre on the patient couch was obtained 2.2 and 0.75 mSv.Gy-1respectively. According to the results,the dose equivalent from emitted photoneutrons is not negligible and therefore treatment conditions should beoptimized. The results of this study emphasized that TLD600 and TLD700 dosimeters inside the polyethylenesphere of neutron probe LB 6411 is an appropriate choice for studying photoneutron production in the vicinity ofthe accelerator

Authors and Affiliations

Samiei F, Nedaie H A, Darestani H, Banaee N, Shagholi N, Mohammadi K, Shahvar A

Keywords

Related Articles

The Correlation Between Fluxes of Balmer Emission Lines of H? and H? and Colors of a Galaxy in VNIR Region

ABSTRACT We have studied the correlation between the flux and colors of a galaxy sample from SDSS, Data Release 13 as measured by the standard Balmer decrement technique in both visible and near-infrared region, coveri...

By A Law of Motion into The Cause of Gravity

This is an essay written by me when I was yet in my younger years, since then I have simplified the same in several other papers. It intrigues me in my old age now to behold my state of mind in those days long ago. This...

Quantum Double Dot as Quantum Computer Unit

In this work, we have investigated the exchange interaction of two electrons in double lateral quantum dot (which is the base of quantum gate) under effect of external magnetic field, electric field and inter dot distanc...

Yang-Mills Families

The Yang-Mills theory structure is based on group theory. It rules the symmetry relationship where the number of potential fields transforming under a same group must be equal to the number of group generators. It define...

Evolution of unstable system.

Scenario of appearance and development of instability in problem of a flow around a solid sphere at rest is discussed. The scenario was created by solutions to the multimoment hydrodynamics equations, which were applied...

Download PDF file
  • EP ID EP653580
  • DOI 10.24297/jap.v6i1.1822
  • Views 63
  • Downloads 0

How To Cite

Samiei F, Nedaie H A, Darestani H, Banaee N, Shagholi N, Mohammadi K, Shahvar A (0). The measurement of photoneutron dose around an 18 MV Varian linear accelerator by TLD600 and TLD700 dosimeters inside the polyethylene sphere of neutron probe LB 6411. JOURNAL OF ADVANCES IN PHYSICS, 6(1), 1049-1057. https://europub.co.uk./articles/-A-653580