The optimization of QAM signals demodulator
Journal Title: Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування - Year 2014, Vol 0, Issue 57
Abstract
Introduction. The processes of signal processing in the quadrature demodulator and the problem of clock synchronization and reference oscillations of quadrature basis providing are considered for a relatively high speed modulation conditions. Main part. The analysis is performed and the basic concepts of the implementation of PLL clock oscillation for optimum decoding of phase of signal elements in the QAM signal are formulated. The approach to unify features a reliable determination of character with no synchronization reference quadrature basis is proposed. The rationale for coherent accumulation of current signal elements for statistical support of clock synchronization process is done. Time values of the signal elements of QAM signal are considered, some rules for operation with circular data buffers while it’s coherent accumulate are formulated. The results of the implementation of coherent clock synchronization in demodulation QAM signals on the example of recommendation ITU-T V.29 is presented. Conclusions. It is shown that the described algorithm of coherent clock synchronization implementation and concepts that formed the basis of its providing reliable clock synchronization during demodulation of QAM signals with high modulation speed.
Authors and Affiliations
O. Pavlov
Predicting of effectiveness of radiofrequency catheter ablation of arrhythmogenic zones in the heart on assessment of electrodes contact with myocardial tissue
Purpose. This work is devoted to method developing for quantify assessment of the electrodes contact with myocardial tissue during catheter radiofrequency ablation. It will allow to perform forecasting destruction effici...
Micromotor for electromechanical reflective polarization phase shifter
The design of micromotor for electromechanical discrete polarizing reflective phase shifter for phased arrays of centimeter and millimeter bands is offer. The stator of the micromotor consists of two sections of the elec...
Two-step method of the measurement data processing of the high-sensitivity radiometric system
Introduction. The radiometry systems for registration low-intensity noise signals are widely used in science and technique. Automation of such apparatus allows to improve the precision of measurements and facilitate inte...
Deformation-sensitive SAW generator
The article deals with the issues of deformational and heat sensitivity of the generators on the surface acoustic waves. Description and results of research are shown
Modeling of high-speed electronic devices
Introduction. The theme of this publication is the modeling of electronic tools that operate in the frequency range from zero to terahertz and higher. Application of new concepts and technologies, including biotechnology...