The results of clinical application of the spring-loaded fixator in osteosynthesis of the medial fractures of femoral neck

Journal Title: Orthopaedics, Traumatology and Prosthetics - Year 2016, Vol 602, Issue 1

Abstract

The share of femoral neck fractures in the structure of injuries enlarges every year due to increasing number of elderly people. Known techniques of osteosynthesis do not provide satisfactory results of treatment in the majority of patients with medial femoral neck fractures. The goal: to improve outcomes of treatment for the patients with medial femoral neck fractures through the development and introduction into clinical practice a new method of bone fragments connecting. The methods: a new device for osteosynthesis of medial femoral neck fractures was worked out and implemented into clinical practice; due to its design features this device can provide primary intertrfragmental compression during surgery and secondary due to potential energy of the compressed spring. A special mechanism of ratchet gearing provides unidirectional telescopic effect and prevents the formation of interfragmental diastase that allow to achieve spontaneous fracture stabilization in postoperative period even with substantial edge resorption of fragments. 114 patients (aged from 23 to 92 years) underwent 115 ope-rations using proposed device from February 2011 to July 2015. Results: positive results in the main clinical group, where proposed fixator was used, were obtained in 89 % cases. Conclusions: the device, that was worked out, is substentiated from anatomical-clinical positions and concepts of resorptive process within the remodeling of bone fragments. The technique is highly effective osteosynthesis even under adverse prognostic for bone-healing of medial femoral neck fractures (II–III type by Pauwels, III–IV typeby Garden) in patients of different age groups. Minimally invasive surgery technique enables organ-savings surgery for elderly patients, including those with co-morbidities.

Authors and Affiliations

Evgeny Pirogov, Olexiy Tyazhelov

Keywords

Related Articles

MORPHOLOGICAL FEATURES STATE OF THE BLOOD SUPPLY AND TISSUE VIABILITY IN FEMORAL AND TIBIAL BONES DURING TOURNIQUET LIMB ISCHEMIA AND RECIRCULATION PERIOD

Detailed studies of histopathological changes and the state of blood supply to the tissues of the limb has not been studied yet. Application with following removing the tourniquet had not been carried out. It remains unc...

Morphology of the articular cartilage of the knee joint in rats with extraarticular femoral bone deformity (Морфологія суглобового хряща колінного суглоба щурів за умов позасуглобової деформації стегнової кістки)

Objective: to assess the structural and functional state of the rat knee after modeling posttraumatic extraarticular deformation of the femur. Methods: experiment was performed in 39 white mature (6 months old) male rat...

BONE FRAGMENTS DISPLACEMENT IN THE TREATMENT OF DIAPHYSEAL FRACTURES AND THEIR IMPORTANCE TO THE PROCESS OF BONE REGENERATION

Methods of fixation are used for the treatment of diaphyseal fractures, which produce structure «fragments – fixation device» with various mechanical properties and the displacement range of fragments. Purpose: to justi...

Differentiation mechanisms of regeneration blastema cells during bone fracture healing

For understanding of reasons of bone nonunion after fractures we have to study the mechanisms which are on the base of cells differentiation. Objective: on the base of clinical and morphologic examination we studied the...

State of venous blood flow in the lower extremitiesof patients with fractures of the tibia after plate osteosynthesis

Violation of antegrade blood flow, deep vein thrombosis and pulmo­nary embolism (PE) presents the complex problem in the treatment of trauma patients. The goal: to examine the state of antegrade blood flow in the vessel...

Download PDF file
  • EP ID EP202209
  • DOI 10.15674/0030-59872016128-33
  • Views 302
  • Downloads 0

How To Cite

Evgeny Pirogov, Olexiy Tyazhelov (2016). The results of clinical application of the spring-loaded fixator in osteosynthesis of the medial fractures of femoral neck. Orthopaedics, Traumatology and Prosthetics, 602(1), 28-33. https://europub.co.uk./articles/-A-202209