Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Reducing Evaporative Losses

Abstract

In this paper a thermodynamic analysis of cooling tower with air-to-air heat exchanger is presented. During manual operation of conventional cooling tower, a good quantity of water is evaporated which requires equivalent amount of makeup water for their condensers. So, in this regard, the thermodynamic model of a cooling with an air to air heat exchanger is developed using engineering equation solver (EES) software and then simulated in different climatic conditions of two major cities of Pakistan namely Karachi and Jamshoro through the period of June & December 2017. The results show a significant variation in water vapor recovery with respect to atmospheric conditions mainly humidity and ambient air temperature. Results reveal that the when a cooling tower coupled with air to air heat exchanger maximum amount of water vapors are recovered at Karachi and ranges up to 67% and 62% in Jamshoro during the month of December.

Authors and Affiliations

Ans Ahmed Memon

Keywords

Related Articles

Anti-Smog Radar Application for Vehicles

Smog is regarded as a dangerous situation for vehicles as the visibility of human fails and a person cannot drive smoothly and safely which can lead to severe accidents and routine disturbances. Hence, “Anti-Smog Radar A...

Measurement of Flow Rate and Impact Force on Different Vanes through Impact of Jet

The objectives of the paper are to conduct an investigation into the reaction force generated by the impact of a jet of water onto various target vanes and to compare between experimental and theoretical forces which are...

Identifying Top Perfomers in the Electrician Training Programme at FSASEC - VUT using Regression Analysis: Who are the stars

The Vaal University of Technology (VUT) has, in its faculty of Engineering and Technology a flagship community engagement project referred to as the French South African Schneider Electric Education Center (FSASEC) where...

Thermodynamic Analysis of Solar assisted vapour absorption air conditioning System

In This study thermodynamic modeling is presented for an air conditioning system by using waste heat of CNG station, also assisted by solar collector. The continuous compression of Natural gas at CNG station results huge...

Effect of Planner Aspect Ratio on Vernacular Masonry Building under Earthquakes

The behavior of a building during earthquakes depends critically on its planner aspect ratio. This paper deals with an evaluation of the seismic performance of vernacular masonry buildings with different planner aspect r...

Download PDF file
  • EP ID EP419952
  • DOI -
  • Views 134
  • Downloads 0

How To Cite

Ans Ahmed Memon (2018). Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Reducing Evaporative Losses. International Journal of Modern Research In Engineering & Management., 1(10), 55-62. https://europub.co.uk./articles/-A-419952