To the issue of corrosion of occluders from beta-zirconium alloy in experimental study of endovascular devices for the closure of arterial duct

Journal Title: Серце і судини - Year 2018, Vol 0, Issue 2

Abstract

The aim — to evaluate the condition of the surface of intact occluders and its corrosion resistance in the experimental study of devices made of b­zirconium alloy after prolonged stay in an animal’s body. Materials and methods. Investigation of occluders for corrosion resistance were conducted in vitro and when introduced into the bloodstream of pigs as a biological model. Samples of the surface of occluders were examined under light and raster electron microscopes initially and in 1, 3 and 6 months after implantation. Results and discussion. Histological examination of the surface of occluders in the area of their implantation and distal from it, in the background of activation of neointima and developing fibrosis, we revealed inclusions of granular and small­fragmented foreign material of black color. Moderate corrosion of the material was found during the microscopic examination of the surface of intact occluders. After the preliminary processing of the implantable products in the ultrasound bath, microscopically, the surface of the intact occluders was coated with an even thin layer of Zr­Ti oxide film, while the implantation of b­zirconium devices in an animal’s body significantly decreased the number of foreign implants on the histological sections. Conclusions. During thermal treatment, a loose film of Zr­Ti oxide is formed on the surface of products of low­modulus b­zirconium alloy. During the implantation of occluders in an animal’s body, the particles of the oxide film can break away from the main material, migrate with the flow of blood and cause (intensify) the reaction to the introduction of an alien body. It has been shown that the previous combined ultrasonic and chemical cleansing of occluders makes it possible to obtain a smooth and relatively «clean» surface of the implantable products. Products of b­zirconium alloy that underwent ultrasound processing and were implanted in the vessel lumen of the experimental animal do not cause excessive proliferation of intima around the elements of the device and more distantly from its localization.

Authors and Affiliations

Yu.  V. Panichkin, V.  P. Zakharova, Yu.  L. Konopliova, A.  Yu. Gavrilishin, E.  V. Beshlyaga, I.  A. Skiba, M.  V. Pogorelov, A.  V. Solodovnik

Keywords

Related Articles

Role of single nucleotide Т786C polymorphism of endothelial NO-synthase gene after myocardial infarction with ST-segment elevation

The aim — of research was to investigate possible associations between single nucleotide T786C polymorphism of endothelial NO‑synthase (eNOS) gene and clinical events in acute period of myocardial infarction with ST segm...

Growth differentiation factor 15 — biomarker of poor prognosis in heart failure

Heart failure (HF) is a major factor contributing to premature death in patients with established cardiovascular (CV) disease. There is a large body of evidence that biological markers, primarily natriuretic peptides, ga...

Association of load-induced increase in left ventricular filling pressure with changes in level of NT-proBNP and left ventricular hypertrophy in patients with arterial hypertension

The aim — to compare the morpho­functional status of left ventricle (LV) and N­terminal fragment of the brain natriuretic peptide precursor (NT­proBNP) levels in patients with arterial hypertension and clinical symptoms...

Results of treatment of patients with carotid artery stenosis in pathology of vision

The aim — to analyze the results of complex treatment of patients with carotid artery stenoses and abnormalities of the organ of vision. Materials and methods. The analysis was conducted of the results of the examinati...

Infrequent causes of thrombophilia

In patients with thyroid dysfunction, various violations of coagulation and fibrinolysis can be observed: from subclinical, with only laboratory changes, to clinically significant thrombosis or fatal hemorrhages. The sta...

Download PDF file
  • EP ID EP332301
  • DOI 10.30978/HV2018238
  • Views 119
  • Downloads 0

How To Cite

Yu.  V. Panichkin, V.  P. Zakharova, Yu.  L. Konopliova, A.  Yu. Gavrilishin, E.  V. Beshlyaga, I.  A. Skiba, M.  V. Pogorelov, A.  V. Solodovnik (2018). To the issue of corrosion of occluders from beta-zirconium alloy in experimental study of endovascular devices for the closure of arterial duct. Серце і судини, 0(2), 38-45. https://europub.co.uk./articles/-A-332301