Abstract

The utility of carbon paste electrode modified with 2-Amino acetophenone isonicotinoyl hydrazone (2- AAINH), for the potentiometric determination of Ni(II) in aqueous medium is demonstrated. The electrode exhibits linear response to Ni(II) over a wide concentration range (7.3×10−8–9.1×10−2) with Nernstian slope of 29±0.5 mV per decade. It has a response time of about 50 s and can be used for a period of two months with good reproducibility. The detection limit of this electrode was 5.0×10−7 M. The proposed electrode shows a very good selectivity for Ni(II) over a wide variety of metal ions. This chemically modified carbon paste electrode was successfully used for the determination of Ni(II) in electronics waste sample solution.

Authors and Affiliations

Mehdi Samizadeh, Mahmoud Ebrahimi

Keywords

Related Articles

Determining the ability of Subjective Global Assessment (SGA) to diagnosis risk of malnutrition in hospitalized patients

Malnutrition is still one of the most common and important problems in hospitals, and caused an increased incidence of adverse events and mortality in hospitalized patients. Since there is no standard instrument as a gol...

Correlation serum level of 25(OH)D and bone density in type 2 diabetes mellitus patients

Bone density has positive relationship with levels of vitamin D, that reduce the risk of fracture. Some studies shows that vitamin D deficiency is not only related to skletal disease, but also to non-skletal disease such...

The Relationships Among Peripheral myelin protein 22, Ghrelin, Cholecystokinin level and Severity of Diabetic Gastroparesis

Gastroparesis occurs in up to 30-50% of patients with chronic complications of diabetes and is associated with significant impairments in both quality of life and diabetic control. The ethical clearance of this study had...

Influence of Root Canal Irrigants on Fracture Resistance of Teeth: A Narrative Review

Various single and combined irrigation solutions and protocols are used during endodontic treatment. There is no review available on the effect of root canal irrigation solutions on root and crown fracture resistance. Th...

Application of Smear Microscopy, Culture and Polymerase Chain Reaction for Diagnosis of Tuberculous Meningitis in Puducherry

Tuberculous meningitis, a serious manifestation of extra pulmonary tuberculosis, needs early diagnosis and treatment for better clinical outcome. Conventional methods are time consuming and less sensitive. This study com...

Download PDF file
  • EP ID EP344686
  • DOI -
  • Views 136
  • Downloads 0

How To Cite

Mehdi Samizadeh, Mahmoud Ebrahimi (2017). Trace measurement of nickel in orthodontic cages with carbon paste electrode modified multi-walled carbon nanotubes by potentiometric method. Journal of Research in Medical and Dental Science, 5(3), 82-87. https://europub.co.uk./articles/-A-344686