Traceability of syphilis antibody detection in preserved samples
Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 5
Abstract
Objective To investigate whether the current retention methods in blood stations can fully meet the traceability requirements of blood test results by analyzing the traceability of retained samples for syphilis antibody testing. Methods Thirty-four one-assay-positive deep-well plate retention samples, 68 double-assay-positive deep-well plate retention samples and 263 negative retention blood braids and corresponding deep-well plate retention samples that expired retention period for syphilis antibody testing from 2014 to 2020 in our center were collected. The TP-ELISA assays of two manufacturers were used for retesting, and the results were recorded and compared with the original results statistically. Results The concordance rate of the double-assay-positive and single-assay-positive samples with their corresponding deep-well plate samples was 98.53%(67/68) and 67.65%(23/34), respectively(P<0.05). Specific results for single-assay-positive syphilis antibody samples and their corresponding deep-well plate retention samples were as follows: 1) Single positive (reagent A): 13 out of 14 original samples were 0.65<S/CO<3.5, weakly positive samples accounted for 92.86%(13/14), of which 4 corresponding deep-well plate retention samples had negative results, respectively, 2 retests in 2015 turned negative at 66.67%(2/3), and 1 retest in 2018 and 2020 each turned negative at 50%(1/2). One sample corresponded to a deep-well plate retention sample with a double-assay-positive result after testing. 2) Single positive (Reagent B): 18 out of 20 samples were original samples 0.84<S/CO<5.3, with weakly positive samples accounting for 90%(18/20), of which 6 corresponded to deep-well plate retention samples with negative results, respectively, 71.43%(5/7) of the 5 retests in 2014 and 33.33%(1/3) of the 1 retest in 2015. Four specimens corresponding to the deep well plate retention samples had double-positive-assay results after testing. The concordance rate between the double-positive-assay syphilis antibody specimens and the corresponding deep-well plate retained samples was 100%(52/52) in all years except 93.75%(15/16) in 2014 and four of the deep-well plate retained samples had significantly higher S/CO values. The concordance rate of syphilis antibody-negative samples with their corresponding blood braids and deep-well plate retention specimens was 100%(263/263). Conclusion Current retention method has significant impact in the traceability of test results for different sample types. The reasons for the differences should be further analyzed, and a more complete and advanced retention method and a more reasonable traceability testing program should be established to meet judicial requirements and reduce costs and consumption.
Authors and Affiliations
Xinmei WANG, Zhaodong FU, Huihui GAO, Wei FEI, Liang ZANG
Clinical application progress of granulocyte transfusion
Granulocyte is granular leukocytes in blood, which play an important role in anti-infection treatment and cancer-killing activity. In clinical, allogeneic granulocyte transfusion can be applied for anti-infection treatme...
Study on the correlation between positive psychological capital and communication ability of phlebotomist in Beijing
Objective To analyze the relevant factors affecting the positive psychological capital and communication ability of phlebotomist in blood stations based on the theory of positive psychology and communication behavior, so...
Effects of three rehydration methods on prevention of on-site and delayed blood donation-related vasovagal responses: a cluster-randomized trial
Objective To compare the effects of 3 rehydration methods before blood donation on the prevention of on-site and delayed blood donation-related vasovagal response (VVR) . Methods From January to June 2021, 6 250 whole bl...
Prevalence of dengue, chikungunya and zika viruses in blood donors in Kunming, China
Objective To investigate the prevalence of zika virus (ZIKV), dengue virus (DENV) and chikungunya virus (CHIKV) infections in blood donors in Kunming, China. Methods A total of 10 662 samples from blood donors in Kunming...
Risk factors of transfusion-related circulating overload in inpatients and their relationship with clinical outcome
Objective To investigate the risk factors of transfusion-related circulating overload (TACO) in hospitalized patients and to analyze its impact on clinical outcome. Methods The clinical data of 295 patients with blood tr...