Transient Performance Improvement of Wind Turbines with Doubly Fed Induction Generators Using Active Damping Control Strategy

Journal Title: روش های هوشمند در صنعت برق - Year 2015, Vol 6, Issue 24

Abstract

This paper Analytically investigates the effects of system and controller parameters and operating conditions on the dynamic and transient behavior of wind turbines (WTs) with doubly-fed induction generators (DFIGs) under voltage dips and wind speed fluctuations. Also, it deals with the design considerations regarding rotor and speed controllers. The poorly damped electrical and mechanical modes of the system are identified, and the effects of system parameters, and speed/rotor controllers on these modes are investigated by modal and sensitivity analyses. The results of theoretical studies are verified by time domain simulations. It is found that the dynamic behavior of the DFIG-based WT under voltage dips is strongly affected by the stator dynamics. Further, it is shown that the closed loop bandwidth of the rotor current control, rotor current damping, DFIG power factor and the rotor back-emf voltages have high impact on the stator modes and consequently on the DFIG dynamic behavior. Moreover, it is shown that the dynamic behavior of DFIG-based WT under wind speed fluctuation is significantly dependent on the bandwidth and damping of speed control loop.

Authors and Affiliations

Saeed Soleymani, Bahador Fani, Mohammad Reza Yousefi

Keywords

Related Articles

Design and simulation of a new sample and hold circuit with a resulation of 12-bit and a sampling rate of 1 GS/s using a dual sampling technique

In this paper, a new sample and hold circuit (S & H) with a 12 bit resolution and sampling rate of 1 GS/s is proposed using dual sampling technique. The dual sampling technique allows the circuit to always operate in hig...

Improved Fiber Bragg Grating Bending-Sensor Using TE/TM Modes

After the advent of optical fibers and cheap respective parts, using fiber optic sensors flourished. Bending is one of the significant parameters by measuring which, using optical fiber sensors, mechanical system mode ca...

A Review on Fault Detection and Diagnosis Methods in Distribution Power Networks

Fault detection and diagnosis algorithms are the methods whose function is determining the fault point in a system according to pre-faulting and post-faulting conditions, and fault detector is a part of system which perf...

Adaptive Control of Nonlinear Systems in the presence of Actuator Failures

This paper presents an adaptive state feedback control scheme for a class of nonlinear systems with unknown parameters, variable control gains and in the presence of unknown time varying actuator failures. The designed c...

Location-aware News Recommendation System with Using Fuzzy Logic

with release of a huge amount of news on the Internet and the trend of users to Web-based news services.it is necessary to have a recommendation system. To grab attentions to news, news services use a number of criteria...

Download PDF file
  • EP ID EP326608
  • DOI -
  • Views 105
  • Downloads 0

How To Cite

Saeed Soleymani, Bahador Fani, Mohammad Reza Yousefi (2015). Transient Performance Improvement of Wind Turbines with Doubly Fed Induction Generators Using Active Damping Control Strategy. روش های هوشمند در صنعت برق, 6(24), 3-16. https://europub.co.uk./articles/-A-326608