Use of Cement Gun for Fixation of Tibia Component in Total Knee Arthroplasty

Journal Title: Malaysian Orthopaedic Journal - Year 2009, Vol 3, Issue 1

Abstract

We evaluated the efficacy of a cement gun to improve the depth of cement penetration in total knee arthroplasty. Ninety-one consecutive patients from two hospitals were recruited for this study. For Group I cement was applied to the tibial baseplate and the proximal tibia with fingers. Group 2 had similar application of cement to the tibial baseplate but cement was pressurized into the proximal tibia using a cement gun.. The knee was kept extended until the cement hardened. Standard post-operative x-rays were reviewed to assess cement penetration into the proximal tibia. The mean cement penetration was 2.1 mm in Group 1 and 3.1 mm in Group 2 and the difference was statistically significant. The use of the cement gun improves cement penetration into the proximal tibia and facilitates early stability of the implant fixation to the bone.

Authors and Affiliations

R Yoga, N Sivapathasundaram, C Suresh

Keywords

Related Articles

Coracoid Process Morphology using 3D-CT Imaging in a Malaysian Population

Introduction: The aims of this study are to define the coracoid process anatomy in a Malaysian population, carried out on patients in Hospital Serdang with specific emphasis on the dimension of the base of coracoid proce...

Pattern of Cortical Fracture following Corticotomy for Distraction Osteogenesis

Corticotomy is an essential procedure for deformity correction and there are many techniques described. However there is no proper classification of the fracture pattern resulting from corticotomies to enable any studies...

Percutaneous Endoscopic Transforaminal Lumbar Discectomy – An Early Experience

Percutaneous endoscopic spinal surgery performed in the awake state offers a new paradigm for treatment of symptomatic lumbar disc prolapse. We report the outcome of 23 patients who underwent this procedure. Visual analo...

Do Age and Co-morbidy, Among other Factors, affect Length of Hospital Stay following Total Knee Arthroplasty

Introduction: The only treatment for grade IV knee osteoarthritis is total knee arthroplasty (TKA) irrespective of the age of the patient. Most of the grade IV OA patient are elderly and most likely to have some comorbid...

Factors Predicting Late Collapse of Distal Radius Fractures

Background: Although fractures of the distal radius are a common clinical presentation, many factors affect instability of these injuries. The aim of this study was to assess the influence of age, sex, distal radial ulna...

Download PDF file
  • EP ID EP299146
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

R Yoga, N Sivapathasundaram, C Suresh (2009). Use of Cement Gun for Fixation of Tibia Component in Total Knee Arthroplasty. Malaysian Orthopaedic Journal, 3(1), 72-77. https://europub.co.uk./articles/-A-299146