Validation of the detection method for residual human coagulation factor Ⅺ in human prothrombin complex
Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 9
Abstract
Objective To establish an enzyme-linked immunosorbent assay (ELISA) method for the determination of residual human coagulation factor Ⅺ in human prothrombin complex and validate the method. Methods Human factor Ⅺ was reacted with the capture antibody coated on the microtiter plate. After appropriate washing steps, biotinylated primary antibody was bound to the captured protein. Excess primary antibody was washed away and bound antibody was reacted with horseradish peroxidase conjugated streptavidin. TMB substrate was used for color development at 450 nm. The dilution reliability, accuracy, specificity, repeatability, intermediate precision, linearity, range and durability were verified. Results The verification results showed that the accuracy and specificity of this method met the experimental requirements, with an average recovery rate of 109.2% and RSD of 6.93%. The repeatability RSD was 6.78%, and the intermediate precision RSD was 6.75%, indicating good precision. The linear regression correlation coefficient of standard curve was 0.999 9, showing good accuracy and precision within the linear range. The durability was verified by the incubation time and the validity period of reagent kit opening. The results showed that the RSD of the incubation time change was 6.62%, indicating that the incubation time of this detection method was controlled between 28 to 32 minutes, and there was no significant impact on the results. The RSD of the detection results before and after the reagent kit was opened and stored under conditions for 7 days was 3.84%, indicating that the preservation of the reagent kit according to the conditions for 7 days after opening has no effect on the FⅪ detection results. Both indicated that the method had good durability. The dilution reliability results showed that there was a "hook" effect in the detection of FⅪ residue in human prothrombin complex, which could be solved by diluting 100 to 200 times. Conclusion This method can be used for the determination of FⅪ residues of human prothrombin complex in laboratory.
Authors and Affiliations
Yong LIU, Yurong YU, Long YANG, Zexiu LI, Yao ZHANG, Jing DENG, Dan LI, Yunhua CHEN, Xuemei ZHAO
Bioinformatics analysis of HBV s gene mutation in blood donor
Objective To analyze the infectious indicators, HBV s gene mutations and changes in bioinformatics characteristics of HBV DNA+ /HBsAg- blood donor. Methods A sample of HBV DNA+ /HBsAg- was screened by PCR method, and HBs...
Effects of overall planning on staff burnout and group blood donation errors
Objective To analyze the causes of staff burnout and various errors during group blood donation in blood centers, and to explore the significance of overall planning to improve above problems. Methods Various errors occu...
β-Lactam antibiotics promoting aging and clearance of RBCs would deteriorate the DIIHA
Objective To analyze the influence of β-lactam antibiotics on RBC aging and clearance by detecting various indicators of aging and clearance on RBCs, as well as the differences in phagocytosis for erythrocytes before and...
Accuracy and feasibility of non-invasive cell-free fetal DNA RhE blood group genotyping
[Objective] To explore the accuracy and feasibility of non-invasive prenatal diagnosis of fetal RhE genotype using cell-free fetal DNA (cff-DNA) from maternal peripheral blood. [Methods] A total of 134 pregnant women wit...
Establishment and capacity analysis of the platelet donor database with HPA and HLA genotype in Nanjing
Objective To establish a known HPA/HLA genotype platelet donor database in Nanjing, analyze the polymorphism of HPA-1~6w, -15 and HLA-A, -B and evaluate the matching probability and appropriate capacity of the database f...