Verus Ring as a New Device to Perform a Safe and Efficient Capsulorhexis in Patients with Corneal Opacities Undergoing Cataract Surgery

Journal Title: Journal of Intensive and Critical Care - Year 2017, Vol 3, Issue 1

Abstract

One of the most difficult and critical step in cataract surgery is making a perfectly circular and properly sized capsulorhexis, allowing the capsular bag to completely envelop uniformly the IOL optic, reducing the incidence of posterior capsular opacification and providing a more predictable effective lens position [1]. And to prevent anterior capusle extension which complicates cataract surgery and might prevent completion of cataract surgery especially in cases that visibility is not optimal like in corneal scars. Some techniques or devices has been developed in order to make this step easier as the Verus ring (Verus capsulorhexis device, Mile High Ophthalmics), a silicone ring-shaped first suggested as an easy-to-use device option for guiding surgeons under training to perform anterior circular curvilinear capsulorhexis, allowing an efficient opening in the anterior capsule, sizing and safe centering a continuous curvilinear capsulorhexis with minimal cost compared to a femtosecond laser [2] which can do the same job but with more cost. Many studies support the theory of the importance of perfect sizing and centering the capsulorhexis on effect lens position. Capsulorhexis is a delicate step during phacoemulsification requiring experience of the surgeon and can be even more challenging in corneal opacities. We are proposing a new use for the Verus ring to perform capsulorhexis in patients with corneal opacity. Verus ring has been pioneered by Dr. Malik Y. Kahook who is the Glaucoma service chief, University of Colorado, Aurora, Colorado.

Authors and Affiliations

Enrique Suarez, Trad Alkadi

Keywords

Related Articles

Coping Patterns in a Mother of a Child with Multiple Congenital Anomalies: A Case Study

Objective: To study the coping pattern of a mother of a child with multiple congenital anomalies (MCAs) based on interview data. Methods: The mother of a child born at Tohoku University Hospital, Japan, who was diagnose...

Is Closed Loop Glucose Control for ICU Patients Just Around the Corner?

Effective glucose control in the Intensive Care Unit (ICU) setting has the potential to lower mortality rates [1], shorten length of stay [2] and decrease overall cost of care [3]. Yet the goal of achieving this control...

Individualizing Optimal Fluid Resuscitation in Patients with Major Burns: Emerging Role for Hydrocortisone, Proteinuria and Brain Natriuretic Peptide

During the last decades tremendous progress has been made in the acute resuscitation of patients with major burns [1,2]. The recognition that large amounts of fluids should be infused during the first hours to days, due...

Improving Healthcare Provider Communication in End of Life Decision Making

End of life decision making in the critical care setting is a complex and stressful event for all involved, including family members, patients and the healthcare team. Communicating end of life needs is a skill that requ...

More than Expectorant: New Scientific Data on Ambroxol in the Context of the Treatment of Bronchopulmonary Diseases

Background:Ambroxol has been established for decades in the treatment of acute and chronic respiratory diseases. A reassessment of the benefit-risk was conducted recently. Objective: What new scientific data, relevant fo...

Download PDF file
  • EP ID EP299876
  • DOI 10.21767/2471-8505.100067
  • Views 53
  • Downloads 0

How To Cite

Enrique Suarez, Trad Alkadi (2017). Verus Ring as a New Device to Perform a Safe and Efficient Capsulorhexis in Patients with Corneal Opacities Undergoing Cataract Surgery. Journal of Intensive and Critical Care, 3(1), 1-3. https://europub.co.uk./articles/-A-299876